RDP Logo PY Transducer Signal Conditioning.

Because PY transducers are not linear, if a linear output is required, a linearising amplifier must be used.

Standard = Available   Not available = Not Available   Optional = Optional S7AC S7TW S7M E309 615 E525/AC E725/AC
Analogue Linearisation Not available Not available Not available Not available Standard Standard2 Not available
Digital Display Linearisation Not available Not available Not available Not available Optional1 Standard2 Standard3
DC supply Standard Standard Not available Not available Optional1 Optional Optional
110/240V ac supply Not available Not available Standard Standard Optional1 Standard Standard
Voltage Output Standard Not available Standard Standard Standard Optional Standard
4-20mA output Standard Standard Standard Standard Standard Optional Standard
Digital Display & Panel Mount Not available Not available Not available Standard Optional1 Standard Standard
In-Line & IP65 Standard Standard Standard Not available Not available Not available Not available
Voltage free trips Not available Not available Optional Standard Optional1 Optional Optional
Peak Store Not available Not available Optional Not available Optional1 Standard Standard
RS232 Output Not available Not available Not available Not available Optional1 Standard Standard
RS485 Output Not available Not available Not available Not available Optional1 Not available Optional
1 This unit is part of a modular system. This facility is available using one of the other system modules
2 Requires polynomial calibration
3 Requires polynomial or multipoint calibration


Due to the RDP Electronics policy of on-going development, specifications may change without notice.
Any modification may affect the specification of our equipment.

Document Reference:- www.rdpelectronics.com/electronics/menu-electronics-inductive-py.htm, updated 20010419

©RDP Electronics Ltd, Grove Street, Heath Town, Wolverhampton, WV10 0PY, United Kingdom.
Tel +44 (0)1902 457512, Fax +44 (0)1902 452000, URL www.rdpelectronics.com, e-mail sales@rdpelectronics.com.