The
Model
221R offers a complete
state-of-the-art solution for
Oxygen Deficiency Monitoring.
Our
standard Model 221R is outfitted
with a complete package of
electronic features and utilizes
a very accurate and reliable
10-year life zirconium oxide
sensor. This combination
provides unmatched stability and
is virtually maintenance free
over its entire life.
Competitive models generally
suffer from undesirable
stability issues causing
frequent and expensive
false/nuisance alarms. The
undesirable drift usually
results from just slight ambient
temperature change or the
unavoidable decline in
electrochemical sensor outputs.
Our
innovative engineering and
sensor technology guarantee
unmatched stability and
performance over a wide
temperature range of 0º to 130º
F, thereby eliminating costly
nuisance alarm issues.
Our
sensor requires no support gases
and can be easily and accurately
calibrated using compressed air.
A standard calibration takes
approximately 1 minute and only
needs to be performed every 6
months.
Given the remarkable stability
over an extreme temperature
range, complete electronics
package, and a compact water
tight NEMA 4X enclosure, the
Model 221R is a perfect fit for
a wide range of applications,
including: clean room, control
rooms, confined spaces,
refrigerator/freezer, and
applications that are
susceptible to routine hose down
requirements.
Click Here For a Free Quote
|
Listed below is a summary of all
the standard features included
with the base Model 221R.
Standard features include:
- Red
backlit 3 ½ digit LCD.
High-resolution and easy to
read from across the room
-
2-Factory preset oxygen
depletion alarms. Set
for OSHA standards of 20.0%
for CAUTION and 19.5% for
DANGER. Relays are Form C
contacts and rated for 5A
@115VAC
- 95db
audible alarm that
sounds when the oxygen level
drops below 19.5% danger set
point
- Battery
back up in the event of
AC power loss
- User
configurable alarm logic:
Fail-safe/non-failsafe,
energize above/below set
point, and latching/non
latching
-
Measurement range is 0-25%.
Optional ranges available
upon request
- Data
logger. Logs data for 15
days continuously @ 1min
intervals.
- Isolated
4-20mA. analog output
- RS-485
bi-directional
communications
- Simple,
intuitive user interface
- Customer
selectable security lockout
feature
- Weather
tight NEMA 4X enclosure
- RFI
protected
-
Unmatched 2-year warranty on
all components including
sensor
- Bright
status LED for any alarm
conditions
- 1 minute
front panel alarm silence
button
|
|
AMI
guarantees
higher
quality
and
exceptional
services
at a
lower
price.
REQUEST
QUOTE
|
|
|
|
|
The Model 221R is a rugged piece
of safety equipment designed for
industrial applications. AMI
leads the industry with the most
complete set of standard
features while maintaining the
industry's most competitive
pricing. UL 61010-1 standard
approval is currently pending.
|
|
|
-
0-25%
Measurement
range
-
Large 3
½ digit
Red
Backlit
digital
display
- 2
fully
adjustable
oxygen
concentration
alarms.
Preset
for OSHA
standards
20.0%
Caution
and
19.5%
Danger
-
Customer
configurable
alarm
logic
-
Status
LED
- 95dB
danger
alarm
preset
for
19.5%
-
Customer
selectable
security
lockout
feature
-
Battery
back-up
-
Isolated
4-20mA
analog
output
signal
- Data
logger
-
RS-485
bi-directional
communications
-
Unmatched
stability
and
repeatability
- RFI
protected
- Wide
operating
temperature
range
- 10
year
life
expectancy
zirconium
oxide
sensor
-
Weather
tight
NEMA 4X
package
-
Optional
remote
oxygen
sensing
probe.
Can be
located
up to
300'
away
from
control
unit
- Gas
connection:
Diffusion
screen.
No pump,
sample
tubing
or
fittings
required
-
Compact
size
|
- Measurement range: 0- 25%
- Red Backlit Digital display: High resolution 3 ½ digit LCD. Reads full scale from 00.0% to 25.0%
- Alarms: 2 fully adjustable oxygen concentration alarms. Preset for OSHA standards
20.0% Caution and 19.5% Danger
Dry contacts 3A. @24VDC/115VAC
- Status LED: indicates Power, Safe Operation, Alarm Conditions and Loss of AC power
- Danger alarm: 95dB danger alarm preset for 19.5%
- Battery back-up: 1 hour
- Analog output signal: Isolated 4-20mA
- Data logger: Logs data for 15 days @ 1 minute intervals, 30 days @ 2 minute intervals, etc.
- Communications: RS-485 bi-directional
- Power requirements: 115VAC < 10watts
- Minimum detection:
0.05% of oxygen
- Repeatability:
+/- 0.1% of range or +/- 0.1% of oxygen, whichever is greater
- Operating temperature range:
0° to 130° F
- Diurnal temperature specification:
< +/- 1 % of scale over temperature range
- 90% full scale response times for specified range
0-25% <12 seconds
- Long life zirconium oxide sensor: 10 year life expectancy
Weather tight NEMA 4X package
- Area Classification: Designed to meet General Purpose UL 61010-1 standard and IP 65 requirements. Approval pending.
- Gas connection: Diffusion screen. No pump or fittings required
- Mounting: Wall mount or 2.0" pipe mount
- Dimensions: 7.0"W x 5.7"H x 4.5"D
- Weight: 4 lbs.
|
|
|
|
|
|
|
|
|
|
Model 1000RS
click photos for
larger view
|
|
|
|
|
Model 1000RS Portable
Trace Oxygen Analyzer With Complete Sample System
|
|
• |
High-resolution 3 ½ digit single range
LCD |
|
• |
10 user-selectable analog output ranges
for: 0-10ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm,
0-.500%, 0-1%, 0-5%, 0-10% and an air cal. range of
0-25% |
|
• |
0-1VDC analog output |
|
• |
Data logger. Logs data for 15 days @
1min intervals, 30 days @ 2min intervals, etc |
|
• |
Patented cellblock technology includes
an integral 4-way gas selector valve: Sample/Bypass,
On/Off, a flow control valve and flow meter all integral
to the compact cell block. This revolutionary cellblock
design shuts or opens both "Sample Gas In" and "Exhaust"
ports simultaneously in the "On /Off" position so as not
to back pressure and damage the sensor. |
|
• |
1-2 year life high-performance
electrochemical sensor. Optional H2S resistant sensor
eliminates the need for an H2S scrubber |
|
• |
Rechargeable NiCad batteries |
|
• |
Very compact and rugged |
|
• |
Designed to meet intrinsic safety
requirements |
|
|
|
|
|
|
|
|
|
Model 2010BR
click photos for
larger view
|
|
|
|
|
Model 2010BR
Wall Mount or 2.0" pipe Mount Hazardous Location Trace
Oxygen Analyzer With Complete Sample System |
|
• |
High resolution 3 ½ digit single range
LCD |
|
• |
Comprehensive state-of-the-art
electronics platform, includes: simple and intuitive
user interface, 2-fully adjustable alarm relay contacts,
programmable alarm configurations, alarm bypass feature,
programmable alarm delays, on board data logger,
3-individual security settings, internal diagnostics,
remaining sensor life indication, etc. |
|
• |
10 Standard analog output ranges:
0-10ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm,
0-.500%, 0-1%, 0-5%, 0-10% and 0-25% |
|
• |
1-5VDC and 4-20mA. analog outputs |
|
• |
Patented cellblock technology. Provides
3-way selector valve: Sample/Span/Off, a flow control
valve and flow meter all integral to the compact cell
block |
|
• |
1-2 year life high-performance
electrochemical sensor. Optional H2S resistant sensor
eliminates the need for an H2S scrubber |
|
• |
Approved by CSA International to UL and
CSA standards as meeting requirements for Class I, Div.
1, Groups B,C,D with flammable gas sample. |
|
|
|
|
|
|
|
|
|
|
|
Watchdog
click
photos for larger view
|
|
|
|
|
The Watchdog.
A Low Cost Trace Oxygen Analyzer With
Complete Sample System |
|
• |
High-resolution 3 ½ digit
single range LCD |
|
• |
10-user selectable analog
output ranges: 0-10ppm, 0-50ppm, 0-100ppm,
0-500ppm, 0-1000ppm, 0-.500%, 0-1%, 0-5%,
0-10% and an air cal. range of 0-25% |
|
• |
1-5VDC or 4-20mA analog
outputs, user selectable |
|
• |
Patented cellblock
technology. Provides 3-way selector valve:
Sample/Span/Off, a flow control valve and
flow meter all integral to the compact cell
block |
|
• |
1-2 year life
high-performance electrochemical sensor.
Optional H2S resistant sensor eliminates the
need for an H2S scrubber |
|
• |
Very compact and rugged |
|
• |
Designed for Class I, Div
2. Groups C,D applications |
|
|
|
|
|
|
|
|
|
|
美国AMI氧分析仪传感器P-2百分含量 美国AMI氧分析仪传感器P-3百分含量 美国AMI氧分析仪传感器P-4百分含量
美国AMI氧分析仪传感器T-1微量 美国AMI便携式微量氧分析仪 美国AMI便携式百分量氧分析仪 美国AMI微量氧分析仪
美国AMI多通道微量氧分析仪 美国AMI防爆微量氧分析仪 美国AMI百分量氧变送器 美国AMI百分量氧分析仪
美国AMI多通道百分量氧分析仪 美国AMI防爆百分量氧分析仪 美国AMI氧气损耗监测器
产品图片 |
产品名称/型号 |
产品简单介绍 |
|
美国AMI氧分析仪传感器P-2百分含量
AMI P-2
|
|
|
美国AMI氧分析仪传感器P-3百分含量
AMI P-3
|
|
|
美国AMI氧分析仪传感器P-4百分含量
AMI P-4
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
日本Figaro气体传感器选型
日本NEMOTO气体传感器
日本FIS气体传感器
英国CITY城市气体 CITY公司/IT公司/SENSORIC公司气体传感器选购指南
英国Alphasense气体传感器选型
瑞士Membrapor气体传感器选型
德国IT公司气体传感器选购资料 德国SENSORIC公司气体传感器 RAE气体传感器气体检测仪 意大利森斯特传感器
Dittrich气体产品
国产气体传感器选型
DCS公司红外产品
VTI公司红外产品
SENSORS公司红外热导产品
爱丁堡公司红外产品Honeywell传感器
SHINYEI传感器
E2V传感器
GE传感器SMARTGAS传感器MSI传感器MEAS传感器
英国SSC气体检测 宝亚呼吸防护设备 Dynament气体传感器德国Schutz
NDIR 红外气体传感器美国MAXTEC产品 美国Teledyne气体分析仪及氧传感器
美国AMI氧分析仪及传感器 美国AII氧分析仪传感器
电化学气体传感器
半导体气体传感器
催化燃烧式气体传感器
固体电解质气体传感器
热传导式气体传感器
红外气体传感器
离子烟雾传感器
机动车用气体传感器
气体变送器/检测仪
O2氧气传感器专场
CO2二氧化碳传感器专场
CH4甲烷传感器专场
室内空气质量监测控制
温湿度监测控制
医疗设备用传感器
红外气体分析元件1
红外气体分析元件2
红外气体分析元件3
激光红外气体分析元件1
激光红外气体分析元件2
激光红外气体分析元件3
气体变送器模块
BW便携式气体检测仪
BW固定式气体检测仪CO传感器
S02传感器H2S传感器
NH3传感器
NO传感器
NO2传感器
CH2O传感器
CL2传感器
HCL传感器
H2传感器O3传感器C2CL4传感器C2H4传感器
HF传感器
HBR传感器
COCL2传感器
HCN传感器
ASCL3传感器
ASF3传感器C4H6传感器
CLO2传感器
SIH2CL2传感器
(CH3传感器NH传感器
GeCL4传感器
I2传感器
PCL3传感器
SICL4传感器
SO2F2传感器
酒精传感器其它 |