Application overview
RANGE |
BACKGROUND GAS |
TELEDYNE INSTRUMENTS |
SENSOR OPTIONS |
Trace |
Less than 1000 ppm CO2 in the background gas
|
311, 316, 317, 318, 3160 |
B-2C |
3000T series |
L-2C |
More than 1000 ppm up to 100% CO2 in the background gas
|
All trace oxygen instruments |
A-2C |
Note: To use the A-2C or B-2C sensor in a 3000T
series instrument, adapter part number B66378 is required. |
Note: The L-2C sensor cannot be used in our
older analog models (300 series). |
Percent |
Less than 1000 ppm CO2 in the background gas |
311P, 320A / P / BRC, 326, 327, 328
|
B-1, B-3 standard;
C-3 for high concentration of O2 |
More than 1000 ppm up to 100% CO2 in the background gas |
A-5 |
Selecting a Teledyne Oxygen Sensor - Detail
CLASS
(click for spec control drwg.) |
PART No. |
APPLICATION |
COMMENTS |
A-1
oxygen sensor |
C6689-A1 |
Ultra-fast response (90% in less than 4
seconds) in the percent oxygen region. |
Use only when B-1 response time is
insufficient. |
A-2C
oxygen sensor |
C6689-A2C |
Used for trace O2 measurements in CO2
containing backgrounds (0.1-100% CO2). CO2 must be present. |
Use where acid gases are present (CO2, HCl,
HCN, etc). CO2 must be present. |
A-2CXL
oxygen sensor |
B74033-A2CXL |
Specially qualified A2C sensor to operate in XL
model analyzers. Low range limit is 0-1 ppm. |
Use where acid gases are present (CO2, HCl,
HCN, etc). CO2 must be present. |
A-2Cl: Obsolete, use A-2C
|
A-3: Obsolete, use A-5
|
A-5
oxygen sensor |
C6689-A5 |
Intermittent or continuous monitoring of
percent O2 in gas mixtures containing 0-100% CO2. 90% response
is time is 45 seconds. |
Has more tolerance to exposure to air than A-3.
No restrictions on CO2 concentration. |
B-1
oxygen sensor |
C6689-B1 |
General purpose percent oxygen analysis where
fast response is desired (90% in less than 7 seconds). |
Use B-3 or C-3 where longer life is required
and response time is relatively unimportant. May be used to spot
check flue gas. |
B-2C
oxygen sensor |
C6689-B2C |
General purpose trace O2 analysis for use in
inert gas and hydrocarbon streams. Low range limit is 0-10 ppm.
|
May be used in CO2 free gas streams containing
highly mobile gases such as H2, He and ethylene. |
INSTA TRACE
oxygen sensor |
B71875 |
Special patented construction provides rapid
recovery, during initial cell installation, to low PPM levels by
reducing the recovery period from several hours to just minutes.
Low range limit is 0-10 ppm. |
Used for trace O2 analysis in inert gas and
hydrocarbon streams.
|
B-2CXL
oxygen sensor |
C6689-B2CXL |
Specially qualified B-2C sensor to operate in
XL model analyzers. Low range limit is 0-1 ppm. |
May be used in CO2 free gas streams containing
highly mobile gases such as H2, He and ethylene. |
B-3
oxygen sensor |
C6689-B3 |
Percent O2 analysis, best compromise between
long life and fast response. |
May be used to spot check flue gas. |
B-4C
oxygen sensor |
C14613-B4C |
Trace O2 cell specifically designed for the
Model 317EXI. |
Same performance as the B-2. |
B-5
oxygen sensor |
C45091-B5 |
Special application cell (non-standard) where
long life and moderately fast response are required; B-5 has a
factor of 3x the life of a B-3. |
Requires 3x the amplifier gain of the B-3.
Expected life is 36 months in air. |
B-5F
oxygen sensor |
C45091-B5F |
Special application cell (non-standard) where
long life and moderately fast response, in the presence of CO2,
are required. |
Uses Type F (acid electrolyte). Requires higher
amplifier gain than normal. 90% response time is 13 seconds.
Expected life in air is 6 months.
|
B-7
oxygen sensor |
C45091-B7 |
Special application cell (non-standard) where
fast response is required; the B-7 has a factor of 3x the life
of a B-1 cell. |
Requires 3x the amplifier gain of the B-1.
Expected life in air is 24 months. |
B-7F
oxygen sensor |
C45091-B7F |
Special application cell (non-standard) where
moderate life and fast response, in the presence of CO2, are
required. |
Requires higher amplifier gain than normal. 90%
response time is 7 seconds. Expected life in air is 3 months.
|
C-1
oxygen sensor |
C6689-C1 |
Rarely used. Schematic for
reference only. |
C-2
oxygen sensor |
C6689-C2 |
Rarely used. Schematic for
reference only. |
C-3
oxygen sensor |
C6689-C3 |
Percent O2 measurements where maximum cell life
is desired (high O2 applications). |
90% response time is 30 seconds. Expected life
in air is 18 months. |
C-5
oxygen sensor |
C45091-C5 |
Special application cell (non-standard) where
long life is required; the C-5 has a factor of 3x the life of a
C-3 cell. |
Requires 3x the amplifier gain of the C-3.
Expected life in air is 54 months. |
C-5F
oxygen sensor |
C45091-C5F |
Special application cell (non-standard) where long life, in
the presence of CO2, is required. |
Requires higher amplifier gain than normal. 90% response
time is 30 seconds. Expected life in air is 9 months. |
C-6
oxygen sensor |
C54090-C6 |
Motion insensitive percent O2 measurements for use in hand
held portable monitors. |
Best cell for OEM safety applications. |
E-1
oxygen sensor |
C14991-E1 |
Special cell with performance characteristic of the C-3 with
5x the life. |
Cell is 2 to 3 times the length of standard MFCs; requires
special mounting. Designed for medical oxygen concentrators.
|
E-2
oxygen sensor |
C57283-E2 |
Long life cell for use is the Model 3290 (for use in
unattended air liquefaction nitrogen skids). |
Has a 3 to 4 years expected life in air. Minimum range
0-1000 ppm.
|
F-1R |
C40371-F1R |
0-1000 ppm CO in Air |
Used in Max 5 and 9950 Portable Combustion Analyzers |
F-3 |
C55194-F3 |
Rarely used. Schematic for
reference only. |
INSTA TRACE - CO2 |
B73016 |
Special patented construction provides rapid
recovery, during initial cell installation, to low PPM levels by
reducing the recovery period from several hours to just minutes.
Used for trace O2 measurements in CO2 containing backgrounds
(0-100% CO2) in the 3000T analyzer series. |
Use where acid gases are present (CO2, HCl,
HCN, etc). CO2 must be present. The INSTA TRACE Micro-fuel Cell
oxygen sensor is capable of measuring below 1 ppm of oxygen
within 15 minutes of installation. |
INSTA TRACE - XL
oxygen sensor |
B73592 |
Special patented construction provides rapid
recovery, during initial cell installation, to low PPM levels by
reducing the recovery period from several hours to just minutes.
Specially qualified sensor to operate in XL model analyzers with
a low range limit of 0-1 ppm. |
Used for trace O2 analysis in inert gas and
hydrocarbon streams.
|
K-1
oxygen sensor |
C43832-K1 |
Smallest Micro-fuel Cell, for use in applications where
small size or multiple sensing requirements exist. |
OEM applications; PC board mountable. |
K-2: Obsolete |
L-2C
oxygen sensor |
C6689-L2C |
Used for general purpose trace oxygen analysis in the 3000T
analyzer series. |
Has a 2 year expected life. |
L-2CI
oxygen sensor |
C6689-L2CI |
Used in the Model 3000T series for trace O2 measurements;
use only in CO2 and H2 background mixtures (e.g. inert gas
generators). |
CO2 concentration should be within +/-20% about some nominal
concentration.
|
S-2C
oxygen sensor |
C6689-S2C |
Trace oxygen cell for use in TurbO2 analyzer. Provides rapid
recovery from air calibration (approximately 20 minutes). |
Low range limit is 0-100 ppm. Has three pin contact system.
|
Z-2C
oxygen sensor |
C6689-Z2C |
Has the same features as the S-2, except configured for use
in the Model 3190. |
Low range limit is 0-100 ppm. Has normal Micro-fuel Cell
contact plate.
|
Storage Recommendations for Micro-Fuel Cells
After the Micro-fuel Cell barrier bag is sealed, the sensor (cell)
continues to react with the oxygen inside the bag.
Eventually, all of the oxygen is consumed and the cell remains in an
inert oxygen-free atmosphere until the bag is opened.
The barrier bag transmits negligible amounts of oxygen and other gases,
and almost no moisture. Thus the cell can be stored for periods up to 6
months and still provide 90% or better of its expected life when finally
placed into use.
Loss of sensor life in storage can be minimized by following a number of
practical stocking procedures.
1) Never remove the cell from the barrier bag until the cell is ready to
be used.
2) Store the sealed cell in a cool storage chamber. Storage temperature
can be room temperature or below. A range of 10 to 22 Celsius is
satisfactory.
3) Avoid any prolonged storage in warm or dry environments. Do not store
the cells in an area that is exposed to direct sunlight.
4) Maintain careful records of the serial numbers for cells put into
stock and for those supplied out of stock. Cells should be supplied from
stock on a first-in, first-out basis.
5) Schedule stock cell orders to coincide with the expected need and
thereby minimize cell storage periods. Although it is possible to store
the cells for reasonably long periods and still maintain cell life, it
is advisable to exercise strict discipline in this matter. For instance,
set a stock period target of three months. By setting a goal to turn
over stock every three months, cell life will be maximized and warranty
issues minimized.
|
Oxygen Monitors |
AX300 Oxygen Analyzer and MX300 Oxygen Monitor
Click
here for complete information about these microprocessor
based units specifically designed for the medical industry
|
See a complete listing of Teledyne's
medical industry distributors. |
|
氧气传感器 便携式氧分析仪 在线氧气分析仪
氢分析仪 医用氧气浓度监测仪 Teledyne 分析仪备件
产品图片 |
产品名称/型号 |
产品简单介绍 |
|
Teledyne 氧分析仪传感器 class B-2C
Teledyne class B-2C
|
|
|
Teledyne 氧分析仪传感器 A-2C
Teledyne A-2C
|
|
|
Teledyne 氧分析仪传感器 A-5
Teledyne A-5
|
|
|
Teledyne 氧分析仪传感器 B-1
Teledyne B-1
|
|
|
Teledyne 氧分析仪传感器 B-2CXL
Teledyne B-2CXL
|
|
|
Teledyne 氧分析仪传感器 B-3
Teledyne B-3
|
|
|
Teledyne 氧分析仪传感器 class L-2C
Teledyne class L-2C
|
|
|
Teledyne 氧分析仪传感器 insta trace
Teledyne insta trace
|
|
|
Teledyne 氧气浓度监护仪电池 R-15
Teledyne R-15
|
|
|
Teledyne 氧浓度检测仪电池 R-17MED
Teledyne R-17MED
|
|
|
Teledyne 氧气浓度检测仪电池 R-22MED
Teledyne R-22MED
|
|
|
Teledyne 氧气浓度检测仪电池 R-22MED
Teledyne R-22MED
|
|
|
Teledyne 氧气浓度监护仪电池 R-24MED
Teledyne R-24MED
|
|
|
Teledyne 氧气浓度监护仪电池 R-23MED
Teledyne R-23MED
|
|
|
Teledyne 氧电池 T-7
Teledyne T-7
|
|
|
Teledyne 氧电池 R-13
Teledyne R-13
|
|
|
Teledyne 氧电池 R-13
Teledyne R-13
|
|
|
Teledyne 氧电池 R-30MED
Teledyne R-30MED
|
|
|
Teledyne 氧传感器(氧电池)
Teledyne
|
|
|
teledyne C06689-B2C
C06689-B2C
|
|
产品图片 |
产品名称/型号 |
产品简单介绍 |
|
|
|
|
3110 便携式氧分析仪
Teledyne 3110
|
|
|
311PC 便携式氧分析仪
Teledyne 311PC
|
|
|
311TCXL 便携式微量氧分析仪
Teledyne 311TCXL
|
|
|
311TC便携式微量氧分析
Teledyne 311TC
|
|
|
|
|
|
美国Teledyne 311便携式氧分析仪
Teledyne 311
|
|
|
Ultrace3000 痕量氧分析仪
Teledyne Ultrace 3000
|
|
|
Insta Trans 氧变送器
Teledyne Insta Trans
|
|
|
3000MB 磁氧分析仪
Teledyne 3000MB
|
|
|
3020M 防爆磁氧分析仪
Teledyne 3020M
|
|
|
3000MA 磁氧分析仪
Teledyne 3000MA
|
|
|
3020P 防爆百分量氧分析仪
Teledyne 3020P
|
|
|
3000PA 百分量氧分析仪
Teledyne 3000PA
|
|
|
3000PB 百分量氧分析仪
Teledyne 3000PB
|
|
|
3010PA 百分量氧分析仪
Teledyne 3010PA
|
|
|
3020T微量氧分析仪
Teledyne 3020T
|
|
|
3000ZA-XL微量氧分析仪
Teledyne 3000ZA-XL
|
|
|
3010TB微量氧分析仪
Teledyne 3010TB
|
|
|
3000TB微量氧分析仪
Teledyne 3000TB
|
|
产品图片 |
产品名称/型号 |
产品简单介绍 |
|
3000TA-XL微量氧分析仪
Teledyne 3000TA-XL
|
|
|
3010TA微量氧分析仪
Teledyne 3010TA
|
|
|
Teledyne微量氧分析仪3000TA
Teledyne 3000TA
|
|
|
|
|
|
2000A 氢分析仪
Teledyne 2000A
|
|
|
MX300医用氧气浓度监护仪
Teledyne Mx300
|
|
|
AX300医用氧气浓度检测仪
Teledyne Ax300
|
|
|
|
|
日本Figaro气体传感器选型
日本NEMOTO气体传感器
日本FIS气体传感器
英国CITY城市气体 CITY公司/IT公司/SENSORIC公司气体传感器选购指南
英国Alphasense气体传感器选型
瑞士Membrapor气体传感器选型
德国IT公司气体传感器选购资料 德国SENSORIC公司气体传感器 RAE气体传感器气体检测仪 意大利森斯特传感器
Dittrich气体产品
国产气体传感器选型
DCS公司红外产品
VTI公司红外产品
SENSORS公司红外热导产品
爱丁堡公司红外产品Honeywell传感器
SHINYEI传感器
E2V传感器
GE传感器SMARTGAS传感器MSI传感器MEAS传感器
英国SSC气体检测 宝亚呼吸防护设备 Dynament气体传感器德国Schutz
NDIR 红外气体传感器美国MAXTEC产品 美国Teledyne气体分析仪及氧传感器
美国AMI氧分析仪及传感器 美国AII氧分析仪传感器
电化学气体传感器
半导体气体传感器
催化燃烧式气体传感器
固体电解质气体传感器
热传导式气体传感器
红外气体传感器
离子烟雾传感器
机动车用气体传感器
气体变送器/检测仪
O2氧气传感器专场
CO2二氧化碳传感器专场
CH4甲烷传感器专场
室内空气质量监测控制
温湿度监测控制
医疗设备用传感器
红外气体分析元件1
红外气体分析元件2
红外气体分析元件3
激光红外气体分析元件1
激光红外气体分析元件2
激光红外气体分析元件3
气体变送器模块
BW便携式气体检测仪
BW固定式气体检测仪CO传感器
S02传感器H2S传感器
NH3传感器
NO传感器
NO2传感器
CH2O传感器
CL2传感器
HCL传感器
H2传感器O3传感器C2CL4传感器C2H4传感器
HF传感器
HBR传感器
COCL2传感器
HCN传感器
ASCL3传感器
ASF3传感器C4H6传感器
CLO2传感器
SIH2CL2传感器
(CH3传感器NH传感器
GeCL4传感器
I2传感器
PCL3传感器
SICL4传感器
SO2F2传感器
酒精传感器其它
|