可定制尺寸的大小
型号 |
敏感面积(mm) |
运行温度 |
峰值信号波长 |
暗电阻(MΩ) |
时间常数(us) |
最致冷温度范围 |
封装 |
AP系列,常温。用于火焰探测等,D*(lpk,
650, 1)典型的1×10^11cm Hz1/2
w-1 |
AP-15 |
1×1 |
+23 |
典型的2.4 |
0.5 - 2,
典型的1 |
200典型的,
最大400 |
无 |
TO-5 |
AP-18 |
1×1 |
TO-8 |
AP-25 |
2×2 |
TO-5 |
AP-28 |
2×2 |
TO-8 |
AP-35 |
3×3 |
TO-5 |
AP-38 |
3×3 |
TO-8 |
AP-68 |
6×6 |
TO-8 |
AP-103 |
10×10 |
TO-3 |
HV系列单元硫化铅探测器,适用于大批量需求,有玻璃窗口(G)和透镜窗口(L),最大温度可达65度,火焰探测 |
AP-15G |
1×1 |
+23 |
典型的2.4 |
0.5 - 2.0,
典型的1 |
200典型的,
最大400 |
|
TO-5 |
AP-14G |
1×1 |
TO-46 |
AP-25G |
2×2 |
TO-5 |
AP-35G |
3×3 |
TO-5 |
AP-15L |
1×1 |
有更高探测率
和响应率 |
TO-5 |
AP-14L |
1×1 |
TO-46 |
AP-25L |
2×2 |
TO-5 |
AP-35L |
3×3 |
TO-5 |
AT1系列,一级致冷(1.2W)硫化铅探测器,用于气体分析,光谱分析,比如水分等 |
AT1-17T |
1×1 |
-25 |
典型的2.5 |
1.5 - 10.0,
典型的3.0 |
800典型的,
最大1600 |
最小45,
典型的50
|
TO-37 |
AT1-18T |
1×1 |
TO-8 |
AT1-27T |
2×2 |
TO-37 |
AT1-28T |
2×2 |
TO-8 |
AT1-37T |
3×3 |
TO-37 |
AT1-38T |
3×3 |
TO-8 |
AT1-66T |
6×6 |
TO-66 |
AT1-68T |
6×6 |
TO-8 |
AT1-103 |
10×10 |
TO-3 |
AT1系列,二级致冷(2.5W)硫化铅探测器,用于气体分析,光谱分析,比如水分等 |
AT2S-16T |
1×1 |
-50 |
典型的2.7 |
3.0 - 20.0,
典型的6.0 |
1750典型的,
最大3500 |
最小70,
典型的75 |
TO-66 |
AT2S-18T |
TO-8 |
AT2S-26T |
2×2 |
-50 |
T0-66 |
AT2S-28T |
TO-8 |
AT2S-36T |
3×3 |
-45 |
TO-66 |
AT2S-38T |
TO-8 |
AT2S-66T |
6×6 |
-25 |
TO-66 |
AT2S-68T |
TO-8 |
|
另有2通道和4通道探测器,可咨询。 |
SCD-13非制冷系列
Ambient Temperature: |
+23°C |
Detector Operating
Temperature |
+23°C |
Detectors tested using 50 V/mm
across the detector and a one
Megohm load resistor in series.
(except AP-1x3, AP-1x5, and
AP-2x5 use 0.5 megohm load
resistor.) |
Standard Specifications
- Electrical |
|
Minimum |
Typical |
Maximum |
Units |
Wavelength of Max.
Response |
2.2 |
2.4 |
|
µm |
D*(500K, 650 Hz,
1Hz) |
7.5 x 108 |
9.4 x 108 |
|
cm Hz1/2
w-1 |
D*( lpk,
650 Hz, 1 Hz) |
8.0 x 1010 |
1.0 x 1011 |
|
cm Hz1/2
w-1 |
Element Resistance
(Dark) |
0.5 |
1.0 |
2.0 |
Megohms/ |
Time Constant (not
measured) |
|
200 |
400 |
µsec |
Rated Element
Temperature |
|
|
+65 |
°C |
When using the
table below, remove parenthesis and
insert appropriate designation for
package type in this space:
Example: 3 for TO-3, 5 for TO-5, 8 for
TO-8.
Model
Number |
Element Size
(mm) |
Responsivity
(lpk, 650)
vw-1 |
Standard Package
Options |
Minimum |
Typical |
AP-1( ) |
1 x 1 |
5.3 x 105 |
8.0 x 105 |
TO-5, TO-8 |
AP-1 x 3( ) |
1 x 3 |
2.1 x 105 |
3.1 x 105 |
TO-5, TO-8 |
AP-1 x 5( ) |
1 x 5 |
1.2 x 105 |
1.8 x 105 |
TO-5, TO-8 |
AP-2( ) |
2 x 2 |
2.7 x 105 |
4.0 x 105 |
TO-5, TO-8 |
AP-2 x 5( ) |
2 x 5 |
0.8 x 105 |
1.2 x 105 |
TO-5, TO-8 |
AP-3( ) |
3 x 3 |
1.7 x 105 |
2.6 x 105 |
TO-5, TO-8 |
AP-48 |
4 x 4 |
1.3 x 105 |
2.0 x 105 |
TO-8 |
AP-58* |
5 x 5 |
1.1 x 105 |
1.6 x 105 |
TO-8 |
AP-68* |
6 x 6 |
9.0 x 104 |
1.4 x 105 |
TO-8 |
AP-103** |
10 x 10 |
5.0 x 104 |
7.5 x 104 |
TO-3 |
* Minimum D*(lpk,
650, 1) >7.0 x 1010
cm Hz1/2 w-1
** Minimum D*(lpk,
650, 1) >6.0 x 1010
cm Hz1/2 w-1
|
带一级制冷TEC系列
Ambient Temperature: |
+25°C |
Detector Operating
Temperature |
-25°C |
Typical
Cooler Power @/or near Max.
Cooling: |
AT1 - 1.0 volts @1.2 amps
AT1S - 1.8 volts @ 1.2 amps |
Standard Specifications
- Electrical
All detector
specifications are at a bias
voltage of 50 V/mm distance
between electrodes applied
across the detector and with a
one megohm load resistor in
series. All specifications apply
at or near maximum cooling with
the heat sink @ +25°C. |
|
Minimum |
Typical |
Maximum |
Units |
Wavelength of Max. Response |
2.4 |
2.5 |
|
µm |
D*(500K, 650 Hz, 1Hz) |
1.0 x 109 |
1.5 x 109 |
|
cm Hz1/2 w-1 |
D*(
lpk, 650 Hz, 1
Hz) |
1.0 x 1011 |
1.5 x 1011 |
|
cm Hz1/2 w-1 |
Element Resistance (Dark) |
1.5 |
3.0 |
10.0 |
Megohms/ |
Time
Constant (not measured) |
|
800 |
1600 |
µsec |
Rated Element Temperature |
|
|
+65 |
°C |
DT@/or near Max. Cooling |
45 |
50 |
|
°C |
For square or rectangular element
sizes and/or packages not listed,
please contact our application
engineers
When using
the table below, remove parenthesis
and insert appropriate designation
for package type in this space:
Example: 6 for TO-66, 7 for
TO-37, 8 for TO-8.
Model
Number |
Element Size
(mm) |
Responsivity
(lpk,
650) vw-1 |
Standard Package
Options |
Minimum |
Typical |
AT1-1( ) |
1 x 1 |
1.3 x 106 |
1.9 x 106 |
TO-37,TO-8 |
AT1-2( ) |
2 x 2 |
6.3 x 105 |
9.5 x 105 |
TO-37,TO-8 |
AT1-3( ) |
3 x 3 |
4.2 x 105 |
6.3 x 105 |
TO-37,TO-8 |
AT1S-4( ) |
4 x 4 |
3.1 x 105 |
4.7 x 105 |
TO-66,
TO-8 |
AT1S-5( )* |
5 x 5 |
2.5 x 105 |
3.8 x 105 |
TO-66,
TO-8 |
AT1S-6( )* |
6 x 6 |
2.0 x 105 |
3.0 x 105 |
TO-66,
TO-8 |
AT1S-103** |
10 x 10 |
1.2 x 105 |
1.8 x 105 |
TO-3 |
* Minimum
D*(lpk,
650, 1) >8.0 x 1010
cm Hz1/2 w-1
**Minimum D*(lpk,
650, 1) >7.0 x 1010
cm Hz1/2 w-1 |
- To specify
thermistor option for
all TE cooled detectors, add the
suffix -T or -TC (calibrated) to
the model number.
带二级制冷(1.5W)
Ambient
Temperature: |
+25°C |
Detector Operating
Temperature |
-35°C |
Typical Cooler Power
@/or near Max. Cooling: |
0.9 volts @1.2 amps |
Standard
Specifications - Electrical
All detector
specifications are at a bias
voltage of 50 V/mm distance
between electrodes applied
across the detector and with
a one megohm load resistor
in series. All
specifications apply at or
near maximum cooling with
the heat sink @ +25°C. |
|
Minimum |
Typical |
Maximum |
Units |
Wavelength of Max.
Response |
2.5 |
2.6 |
|
µm |
D*(500K, 650 Hz, 1Hz) |
1.6 x 109 |
2.7 x 109 |
|
cm Hz1/2
w-1 |
D*(
lpk, 650
Hz, 1 Hz) |
1.5 x 1011 |
2.5 x 1011 |
|
cm Hz1/2
w-1 |
Element Resistance
(Dark) |
2.5 |
5.0 |
15.0 |
Megohms/ |
Time Constant (not
measured) |
|
1250 |
2500 |
µsec |
Rated Element
Temperature |
|
|
+65 |
°C |
DT@/or near Max.
Cooling |
55 |
60 |
|
°C |
For square or rectangular element
sizes and/or packages not listed
When using
the table below, remove parenthesis
and insert appropriate designation
for package type in this space:
Example: 6 for TO-66, 7 for
TO-37, 8 for TO-8.
Model
Number |
Element Size
(mm) |
Responsivity
(lpk,
650) vw-1 |
Standard Package
Options |
Minimum |
Typical |
AT2-1( ) |
1 x 1 |
1.3 x 106 |
2.0 x 106 |
TO-37,
TO-8 |
AT2-2( ) |
2 x 2 |
6.6 x 105 |
1.0 x 106 |
TO-37,
TO-8 |
AT2-3( ) |
3 x 3 |
4.3 x 105 |
6.4 x 105 |
TO-37,
TO-8 |
AT2-4( )* |
4 x 4 |
3.2 x 105 |
4.8 x 105 |
TO-37,
TO-8 |
* Minimum
D*(lpk, 650, 1)
>1.0 x 1011
cm Hz1/2 w-1 |
- To specify
thermistor option for
all TE cooled detectors, add the
suffix -T or -TC (calibrated) to
the model number.
带二级制冷(2.5W)
Ambient Temperature: |
+25°C |
Detector Operating
Temperature |
See model types below |
Typical Cooler Power
@/or near Max. Cooling: |
1.8 volts @1.2 amps |
Standard
Specifications - Electrical
All detector
specifications are at a bias
voltage of 50 V/mm distance
between electrodes applied
across the detector and with
a one megohm load resistor
in series. All
specifications apply at or
near maximum cooling with
the heat sink @ +25°C. |
|
Minimum |
Typical |
Maximum |
Units |
Wavelength of Max.
Response |
2.6 |
2.7 |
|
µm |
D*(500K, 650 Hz, 1Hz) |
2.2 x 109 |
3.3 x 109 |
|
cm Hz1/2
w-1 |
D*(lpk, 650
Hz, 1 Hz) |
2.0 x 1011 |
3.0 x 1011 |
|
cm Hz1/2
w-1 |
Element Resistance
(Dark) |
3.0 |
6.0 |
20.0 |
Megohms/ |
Time Constant (not
measured) |
|
1750 |
3500 |
µsec |
Rated Element
Temperature |
|
|
+65 |
°C |
DT@/or near Max.
Cooling |
70 |
75 |
|
°C |
For square or rectangular element
sizes and/or packages not listed,
When using
the table below, remove parenthesis
and insert appropriate designation
for package type in this space:
Example: 6 for TO-66, 8 for
TO-8.
Model
Number |
Element Size
(mm) |
Responsivity
(lpk,
650) vw-1 |
Operating Temp |
Standard Package
Options |
Minimum |
Typical |
AT2S-1( ) |
1 x 1 |
1.4 x 106 |
2.1 x 106 |
-50°C |
TO-66,
TO-8 |
AT2S-2( ) |
2 x 2 |
7.0 x 105 |
1.1 x 106 |
-50°C |
TO-66,
TO-8 |
AT2S-3( ) |
3 x 3 |
4.3 x 105 |
6.5 x 105 |
-45°C |
TO-66,
TO-8 |
AT2S-4( ) |
4 x 4 |
3.3 x 105 |
5.0 x 105 |
-40°C |
TO-66,
TO-8 |
AT2S-5( )* |
5 x 5 |
2.7 x 105 |
4.0 x 105 |
-35°C |
TO-66,
TO-8 |
AT2S-6( )* |
6 x 6 |
2.4 x 105 |
3.6 x 105 |
-25°C |
TO-66,
TO-8 |
* Minimum
D*(lpk,
650, 1) >1.0x1011
cm Hz1/2 w-1 |
- To specify
thermistor option for
all TE cooled detectors, add the
suffix -T or -TC (calibrated) to
the model number.
|