可定制探测器
型号 |
芯片面积(mm) |
运行温度 |
峰值信号波长 |
D*cm
Hz1/2 w-1 |
Responsivity
(lpk, 1000) vw-1
|
暗电阻(M) |
时间常数(us) |
最大致冷,温度范围 |
封装 |
D*(500K, 1000 Hz, 1Hz) |
D*( lpk,
1000 Hz, 1 Hz) |
Min |
Typ |
|
|
|
|
BXP系列室温硒化铅探测器 |
BXP-15 |
1×1 |
+23 |
典型3.8 |
min7*10^9,
typ1.5*10^10 |
min1*10^8,
typ1.5*10^9 |
1.5*10^4 |
3*10^4 |
0.1-2.5,
典型的0.8 |
典型的2
最大5 |
N/A |
TO-5 |
BXP-18 |
TO-8 |
BXP-25 |
2×2 |
7.5*10^3 |
1.5*10^4 |
TO-5 |
BXP-28 |
TO-8 |
BXP-35 |
3×3 |
5*10^3 |
1*10^4 |
TO-5 |
BXP-38 |
TO-8 |
BXP-68 |
6×6 |
min6*10^9 |
2.5*10^3 |
5*10^3 |
TO-8 |
BXP-103 |
10×10 |
min5*10^9 |
1.5*10^3 |
3*10^3 |
TO-3 |
BXT1系列一级致冷TEC(1.2W)硒化铅探测器 |
BXT1-17T |
1×1 |
-25 |
典型4.2 |
min1.4*10^10
typ2.8*10^10 |
min1.9*10^9
typ3.9*10^9 |
4.0*10^4 |
6*10^4 |
0.5-10.0
典型4.0
|
典型的6
最大12 |
typ45
max50 |
TO-37 |
BXT1-18T |
TO-8 |
BXT1-27T |
2×2 |
2.0*10^4 |
3*10^4 |
TO-37 |
BXT1-28T |
TO-8 |
BXT1-37T |
3×3 |
1.33*10^4 |
2*10^4 |
TO-37 |
BXT1-38T |
TO-8 |
BXT1-66T |
6×6 |
1.0*10^10 |
6.7*10^3 |
1.0*10^4 |
TO-66 |
BXT1-68T |
TO-8 |
BXT1-103T |
10×10 |
8*10^9 |
4.0*10^3 |
6.0*10^3 |
TO-3 |
BXT2系列一级致冷TEC(1.5W)硒化铅探测器 |
BXT2-18T |
1×1 |
-35 |
典型4.3 |
min2.2*10^9
typ4.2*10^9 |
min1.6*10^10
typ3.0*10^10 |
6.6*10^4 |
1.0*10^5 |
1-15.0
典型5.0 |
典型的9
最大20 |
typ60
|
TO-8 |
BXT2-28T |
2×2 |
3.3*10^4 |
5*10^4 |
TO-8 |
BXT2-38T |
3×3 |
2.2*10^4 |
3.3*10^4 |
TO-8 |
BXT2-48T |
4×4 |
1.6*10^4 |
2.5*10^4 |
TO-8 |
BXT2S系列一级致冷TEC(2.5W)硒化铅探测器 |
BXT2S-16T |
1×1 |
-50 |
典型
4.5 |
min2.0*10^10
typ3.5*10^10 |
min2.9*10^9
typ2.5*10^10 |
1.0×10^5 |
1.5*10^5 |
1-20.0
典型6.0 |
典型的12
最大25 |
min70
typ75 |
TO-66 |
BXT2S-18T |
TO-8 |
BXT2S-26T |
2×2 |
-50 |
5.0*10^4 |
7.5*10^4 |
TO-66 |
BXT2S-28T |
TO-8 |
BXT2S-36T |
3×3 |
-45 |
3.3*10^4 |
3.75*10^4 |
TO-66 |
BXT2S-38T |
TO-8 |
BXT2S-66T |
6×6 |
-25 |
min1.5*10^10 |
1.65*10^4 |
2.5*10^4 |
TO-66 |
BXT2S-68T |
TO-8 |
|
另有2通道和4通道的探测器,可咨询。 |
BXP系列室温硒化铅探测
Ambient
Temperature: |
+23°C |
Detector
Operating Temperature |
+23°C |
Detectors tested using
35 V/mm across the
detector and a one
Megohm load resistor in
series. |
Standard
Specifications -
Electrical
|
|
Minimum |
Typical |
Maximum |
Units |
Wavelength of Max.
Response |
3.6 |
3.8 |
|
µm |
D*(500K,
1000 Hz, 1Hz) |
1.0 x 108 |
1.5 x 109 |
|
cm Hz1/2 w-1 |
D*(
lpk,
1000 Hz, 1 Hz) |
1.0 x 109 |
1.5 x 1010 |
|
cm Hz1/2 w-1 |
Element
Resistance (Dark) |
0.1 |
0.8 |
2.5 |
Megohms/ |
Time
Constant (not measured) |
|
2 |
5 |
µsec |
Rated
Element Temperature |
|
|
+55 |
°C |
|
When using the
table below, remove parenthesis
and insert appropriate
designation for package type in
this space.
Example: 5 for TO-5, 8 for TO-8.
Model
Number |
Element Size
(mm) |
Responsivity
(lpk,
1000) vw-1 |
Standard Package
Options |
Minimum |
Typical |
BXP-1( ) |
1 x 1 |
1.5 x 104 |
3.0 x 104 |
TO-5,TO-8 |
BXP-2( ) |
2 x 2 |
7.5 x 103 |
1.5 x 104 |
TO-5,TO-8 |
BXP-3( ) |
3 x 3 |
5.0 x 103 |
1.0 x 104 |
TO-5,TO-8 |
BXP-48 |
4 x 4 |
3.75 x 103 |
7.5 x 103 |
TO-8 |
BXP-58 * |
5 x 5 |
3.0 x 103 |
6.0 x 103 |
TO-8 |
BXP-68 * |
6 x 6 |
2.5 x 103 |
5.0 x 103 |
TO-8 |
BXP-103** |
10 x
10 |
1.5 x 103 |
3.0 x 103 |
TO-3 |
* Minimum D*(
lpk,
1000 Hz, 1 Hz) >
8 x 109 cm Hz1/2
w-1
** Minimum D*(
lpk,
1000 Hz, 1 Hz) >
6 x 109 cm Hz1/2
w-1
1/4 x 1/4mm, 1/2 x
1/2mm, 1 x 3mm, 1 x 5mm
& 2 x 5mm element sizes
also available. |
|
BXT1系列带一级制冷TEC
Ambient
Temperature: |
+25°C |
Detector
Operating
Temperature |
-25°C |
Typical
Cooler Power
@/or near
Max.
Cooling: |
BXT1
-1.0 volts
@1.2 amps
BXT1S - 1.8
volts @ 1.2
amps |
Standard
Specifications
- Electrical
All
detector
specifications
are at a
bias voltage
of 25 V/mm
distance
between
electrodes
applied
across the
detector and
with a load
resistor in
series. All
specifications
apply at or
near maximum
cooling with
the heat
sink @
+25°C. |
|
Minimum |
Typical |
Maximum |
Units |
Wavelength
of Max.
Response |
4.0 |
4.2 |
|
µm |
D*(500K,
1000 Hz,
1Hz) |
1.9 x 109 |
3.9 x 109 |
|
cm Hz1/2
w-1 |
D*(
lpk,
1000 Hz, 1
Hz) |
1.4 x 1010 |
2.8 x 1010 |
|
cm Hz1/2
w-1 |
Element
Resistance
(Dark) |
0.5 |
4.0 |
10.0 |
Megohms/ |
Time
Constant
(not
measured) |
|
6 |
12 |
µsec |
Rated
Element
Temperature |
|
|
+55 |
°C |
DT@/or
near Max.
Cooling |
45 |
50 |
|
°C |
|
Other
detector
configurations
available upon
request,
When
using the table
below, remove
parenthesis and
insert appropriate
designation for
package type in this
space.
Example: 5 for TO-5,
8 for TO-8.
Model
Number |
Element Size
(mm) |
Responsivity
(lpk,
1000) vw-1 |
Standard
Package
Options |
Minimum |
Typical |
BXT1-1(
) |
1 x 1 |
40000 |
60000 |
TO-37,TO-8 |
BXT1-2(
) |
2 x 2 |
20000 |
30000 |
TO-37,TO-8 |
BXT1-3(
) |
3 x 3 |
13300 |
20000 |
TO-37,TO-8 |
BXT1S-4(
) |
4 x 4 |
10000 |
15000 |
TO-66, TO-8 |
BXT1S-5(
)* |
5 x 5 |
8000 |
12000 |
TO-66, TO-8 |
BXT1S-6(
)* |
6 x 6 |
6700 |
10000 |
TO-66, TO-8 |
BXT1S-103** |
10 x 10 |
4000 |
6000 |
TO-3 |
* Minimum
D*(
lpk,
1000, 1)
>1.0 x
1010
cm Hz1/2
w-1
** Minimum
D*(
lpk,
1000, 1)
>8.0 x
109
cm Hz1/2
w-1 |
|
- To specify
thermistor option
for all TE cooled
detectors, add the
suffix -T or -TC
(calibrated) to the
model number.
BTX2系列带二级制冷TEC(1.5W)
Ambient Temperature: |
+25°C |
Detector Operating Temperature |
-35°C |
Typical Cooler Power @/or near Max. Cooling: |
0.9 volts @1.2 amps |
Standard Specifications - Electrical
All detector specifications are at a bias voltage of 25 V/mm distance between electrodes applied across the detector and with a load resistor in series. All specifications apply at or near maximum cooling with the heat sink @ +25°C. |
|
Minimum |
Typical |
Maximum |
Units |
Wavelength of Max. Response |
4.1 |
4.3 |
|
µm |
D*(500K, 1000 Hz, 1Hz) |
2.2 x 109 |
4.2 x 109 |
|
cm Hz1/2 w-1 |
D*( lpk, 1000 Hz, 1 Hz) |
1.6 x 1010 |
3.0 x 1010 |
|
cm Hz1/2 w-1 |
Element Resistance (Dark) |
1.0 |
5.0 |
15.0 |
Megohms/ |
Time Constant (not measured) |
|
9 |
20 |
µsec |
Rated Element Temperature |
|
|
+55 |
°C |
DT@/or near Max. Cooling |
55 |
60 |
|
°C |
|
Other
detector
configurations
available
upon
request,
When
using
the
table
below,
remove
parenthesis
and
insert
appropriate
designation
for
package
type in
this
space.
Example:
5 for
TO-5, 8
for
TO-8.
Model
Number |
Element Size
(mm) |
Responsivity
(lpk, 1000) vw-1 |
Standard Package
Options |
Minimum |
Typical |
BXT2-1( ) |
1 x 1 |
66000 |
100000 |
TO-37,TO-8 |
BXT2-2( ) |
2 x 2 |
33000 |
50000 |
TO-37,TO-8 |
BXT2-3( ) |
3 x 3 |
22000 |
33000 |
TO-37,TO-8 |
BXT2-4( ) |
4 x 4 |
16000 |
25000 |
TO-8 |
|
-
To specify
thermistor
option
for all TE
cooled
detectors,
add the
suffix -T or
-TC
(calibrated)
to the model
number.
BXT2S系列带二级制冷TEC(2.5W)
Ambient Temperature: |
+25°C |
Detector Operating Temperature |
See model types below |
Typical Cooler Power @/or near Max. Cooling: |
1.8 volts @1.2 amps |
Standard Specifications - Electrical
All detector specifications are at a bias voltage of 25 V/mm distance between electrodes applied across the detector and with a load resistor in series. All specifications apply at or near maximum cooling with the heat sink @ +25°C. |
|
Minimum |
Typical |
Maximum |
Units |
Wavelength of Max. Response |
4.3 |
4.5 |
|
µm |
D*(500K, 1000 Hz, 1Hz) |
2.9 x 109 |
5.2 x 109 |
|
cm Hz1/2 w-1 |
D*( lpk, 1000 Hz, 1 Hz) |
2.0 x 1010 |
3.5 x 1010 |
|
cm Hz1/2 w-1 |
Element Resistance (Dark) |
1.0 |
6.0 |
20.0 |
Megohms/ |
Time Constant (not measured) |
|
12 |
25 |
µsec |
Rated Element Temperature |
|
|
+55 |
°C |
DT@/or near Max. Cooling |
Scroll to see chart below |
|
°C |
|
Other detector configurations available upon request,
When using the table below, remove parenthesis and insert appropriate designation for package type in this space. Example: 6 for TO-66, 8 for TO-8.
Model
Number |
Element Size
(mm) |
Responsivity
( lpk, 1000) vw-1 |
Operating Temp |
Standard Package
Options |
Minimum |
Typical |
BXT2S-1( ) |
1 x 1 |
100000 |
150000 |
-50°C |
TO-66, TO-8 |
BXT2S-2( ) |
2 x 2 |
50000 |
75000 |
-50°C |
TO-66, TO-8 |
BXT2S-3( ) |
3 x 3 |
33000 |
50000 |
-45°C |
TO-66, TO-8 |
BXT2S-4( ) |
4 x 4 |
25000 |
37500 |
-40°C |
TO-66, TO-8 |
BXT2S-5( )* |
5 x 5 |
20000 |
30000 |
-35°C |
TO-66, TO-8 |
BXT2S-6( )* |
6 x 6 |
16500 |
25000 |
-25°C |
TO-66, TO-8 |
* Minimum D*( lpk, 1000, 1) >1.5 x 1010 cm Hz1/2 w-1 |
|
- To specify thermistor option for all TE cooled detectors, add the suffix -T or -TC (calibrated) to the model number.
|