Sensor for gas Oxygen O2, 30% vol
Sensor for gas Oxygen O2, 30% vol. in CTL-4 (4-series) housing
Micro Sensor for gas Oxygen O2, 30% vol
Sensor for gas Oxygen O2, 100% vol
Micro Sensor for gas Carbon monoxide CO, 20 ppm
Micro Sensor for gas Carbon monoxide CO, 100 ppm
Combustible Gas Sensor (Pellistor and Compensator), 100% LEL
Combustible Gas Sensor (Pellistor), 100% LEL
Combustible Gas Sensors (Pellistor + Compensator) in CTL-4, mini,
micro casing NEW
Infra-red Combustible Gas Sensor, 100% LEL
Sensor for gas Hydrogen H2, 5% vol
Chemcassette for gas detection by use in some photocolorimeter
Description of SEC-Sensor by way of example H2-SEC-Sensor
SEC-Sensor for gas Hydrogen H2,20.000 ppm (2% vol.)
SEC-Sensor for gas Hydrogen Sulphide H2S, 100 ppm
SEC-Sensor for gas Carbon Monoxide CO.1000 ppm
SEC-Sensor H2 with output 6-24 V in 4 Series housing
SEC-Sensors in 4-SEries Housing, Circuit Diagram, Protection Cap,
Micro-Sensor Housing
型号 |
图片 |
输出 |
测量气体 |
测量范围 |
OX 3P |
|
150-500mV在空气中 |
0-30%VOL
O2 |
俄罗斯进口,标准4系列封装氧气传感器,空气中寿命大于10年,质保30个月,内置变送器,大输出电压,运行温度范围宽-35度-
50度。 |
Ox 9F |
|
150-500mV在空气中 |
0-30%VOL O2 |
俄罗斯进口,M16*1螺纹接口,兼容KE-25F3,空气中寿命大于10年,质保30个月,内置变送器,大输出电压,运行温度范围宽-35度-
50度,用于燃烧分析 |
Ox 9E |
|
150-500mV在空气中 |
0-30%VOL O2 |
俄罗斯进口,M16*1螺纹接口,兼容KE-25F3,空气中寿命大于10年,质保30个月,内置变送器,大输出电压,运行温度范围宽-35度-
50度,用于烟气分析 |
Ox 9 |
|
150-320mV在空气中 |
0-30%VOL O2 |
俄罗斯进口,M16*1螺纹接口,兼容KE-25F3,空气中寿命大于10年,质保30个月,内置变送器,大输出电压,运行温度范围宽-35度-
50度,用于生命安全和通用目的 |
Ox
29N |
|
500-1500mV在空气中 |
0-21%VOL O2 |
俄罗斯进口,M16*1螺纹接口,兼容KE-25F3,空气中寿命大于10年,质保30个月,内置变送器,大输出电压,运行温度范围宽-35度-
50度,用于惰性气体中的氧气浓度测量 |
Ox 10 |
|
150-320mV在空气中 |
0-100%VOL O2 |
俄罗斯进口,M16*1螺纹接口,兼容KE-25F3,空气中寿命大于10年,质保30个月,内置变送器,大输出电压,运行温度范围宽-35度-
50度,用于通用技术性目的 |
Sensor for gas
Oxygen O2, 30% vol.
|
|
Features:
� very long life time
� high reliability
� built-in transmitter |
Technical Data |
|
Sensor type |
Oxigen-O2-2E-30% |
Measuring principle |
amperometric 2-electrode-sensor |
Measuring range |
0-30% vol. O2 |
Sensitivity range |
1 50-500 mV/20.8%vol.O2 |
Long term sensitivity drift |
<15% per 3 years, <30% per 10 years |
Deviation from linearity |
<0.3% vol. O2 inside of range 0-30%
vol. O2 |
Zero voltage at 20°C |
<0.3% vol. O2 |
Response time 1 9o (s) at 20°C |
<20 seconds, typical 12 seconds |
Effect of temperature on sensitivity |
<5% inside of range -20°C to +50°C,
built-in transmitter with temperature
compensation |
Pressure dependence |
linear |
Operating conditions |
-35°C to +50°C; 0 to 98% r.H.
(non-condensed) |
Best storage conditions |
+5°C to +20°C; 40 to 60% r.H. |
Sensor life expectancy |
>10 years at 20.8% vol.O2, at 20°C |
Warranty |
30 months |
Dimensions |
height 16.5 mm, diameter 22.5 mm |
Sensor transmitter output |
two wires: "+mV"-red, "ground"-black |
Imput impedance of user's Electronic
circuit |
>2 MQ, >2 MO by switch off of el.
circuit |
None cross sensitivity at 20°C by |
Carbon monoxide <10%vol.
Carbon dioxide <30%vol.
Hydrogen <30%vol.
Mainly VOCs ~ %-range |
Sensor for gas Oxygen O2,
30% vol. in CTL-4 (4-series)
housing
|
|
Features:
� very long life
time
� high reliability
� built-in
transmitter |
Technical Data |
|
Sensor type |
Oxigen-O2-2E-30% |
Measuring
principle |
amperometric
2-electrode-sensor |
Measuring range |
0-30% vol. O2 |
Sensitivity range |
150-500
mV/20.8%vol.O2 |
Long term
sensitivity drift |
<15% per 3
years, <30% per 10
years |
Deviation from
linearity |
<0.3% vol. O2
inside of range
0-30% vol. O2 |
Zero voltage at
20°C |
<0.3% vol. O2 |
Response time 1
9o (s) at 20°C |
<20 seconds,
typical 12 seconds |
Effect of
temperature on
sensitivity |
<5% inside of
range -20°C to
+50°C, built-in
transmitter with
temperature
compensation |
Pressure
dependence |
linear |
Operating
conditions |
-35°C to +50°C;
0 to 98% r.H.
(non-condensed) |
Best storage
conditions |
+5°C to +20°C;
40 to 60% r.H. |
Sensor life
expectancy |
>10 years at
20.8% vol.O2, at
20°C |
Warranty |
30 months |
Dimensions |
CTL-4 housing
(4-Series) height 18
mm, diameter 20 mm |
Sensor
transmitter output |
two pins, Ø 1.6
mm |
Imput impedance
of user's Electronic
circuit |
>2 MΩ, >2 MΩ by
switch off of el.
circuit |
None cross
sensitivity at 20°C
by |
Carbon monoxide
<10%vol.
Carbon dioxide
<30%vol.
Hydrogen <30%vol.
Mainly VOCs ~
%-range |
|
|
Micro Sensor for gas
Oxygen O2, 30% vol.
|
|
Features:
� small
� long life time
� high reliability
� built-in
transmitter |
Technical Data |
|
Sensor type |
Oxigen-O2-2E-30%-micro |
Measuring
principle |
amperometric
2-electrode-sensor |
Measuring range |
0-30% vol. O2 |
Sensitivity range |
90-250
mV/20.8%vol.O2 at
20°C |
Long term
sensitivity drift |
< 8% per 12
months, <20% per 3
years |
Deviation from
linearity |
<1% |
Zero voltage at
20°C |
<4mV |
Response time 1
90 (s) at 20°C |
<20 seconds,
typical 10 seconds |
Effect of
temperature on
sensitivity |
<5% inside of
range -20°C to
+45°C, built-in
transmitter with
temperature
compensation |
Pressure
dependence |
linear |
Operating
conditions |
-35°C to +45°C;
0 to 98% r.H.
(non-condensed) |
Best storage
conditions |
+5°C to +20°C;
40 to 60% r.H. |
Sensor life
expectancy |
>3 years at
20.8% vol.O2, at
20°C |
Warranty |
12 months |
Dimensions |
height 1 1 .7
mm, diameter 1 1 .5
mm |
Sensor
transmitter output |
two wires:
"+mV"-red,
"common"-white |
Imput impedance
of user's Electronic
circuit |
>100 MO, >30 MO
by switch off of el.
circuit |
None cross
sensitivitys at 20°C
by |
Carbon monoxide
<10%vol.
Carbon dioxide
<30%vol.
Hydrogen <30%vol.
Mainly VOCs ~
%-range |
|
|
|
|
|