压力传感器
供应 压力传感器,分为数字和模拟两种。该系列 压力传感器具有能效高、稳定性好、准确度高、适合恶劣环境使用的特点。广泛应用于:工业生产、环境保护、测量、医学领域。
Model
|
HDU
|
HMU
|
Pressure ranges
|
100 mbar to 5 bar
|
100 mbar to 10 bar
|
1 to 70 psi
|
1 to 70 psi
|
Pressure type
|
Absolute, Gage,
Differential
|
Absolute, Gage,
Differential
|
Output signal
|
100mV (FSO)
|
100mV (FSO)
|
Thermal effects
|
Offset
|
±0.02 %FSS/°C
|
±0.02% FSS/°C
|
Span
|
-0.2% FSS/°C
|
-0.2% FSS/°C
|
Bridge impedance
|
0.26 %/°C
|
0.26 %/°C
|
Temp. range
operating
|
-40-85°C
|
-40-85°C
|
Dimensions without
connections
|
12×15×7mm³
|
10×13×6mm³
|
Features
|
Analogue sensor
with
nearly unlimited resolution
|
Analogue sensor
with
nearly unlimited resolution
|
Cost-effective
basic pressure sensor
|
Cost-effective
basic pressure sensor
|
Increased media
compatibility
|
Model
|
HCL
|
HDO
|
HRO
|
Pressure ranges
|
5 to 75 mbar
|
10 mbar to 5 bar
|
10 mbar to 10 bar
|
2 to 30 inH2
|
4 inH2O to 70 ps
|
4 inH2O to 150 psi
|
Pressure type
|
Gage, Differential
|
Absolute, Gage,
Differential
|
Gage, Differential
|
Output signal
|
20mV (FSO)
|
90mV (FSO)
|
90mV (FSO)
|
Accuracy,
non-linearity
|
±0.05 %FSO
|
±0.1 %FSO (P-grade)
|
±0.25 %FSS
|
±0.2 %FSO (H-grade)
|
Temp. range
compensated
|
0-70°C
|
0-50°C
|
0-70°C
|
Temp. range
operating
|
-25-85°C
|
-40-85°C
|
-25-85°C
|
Dimensions without
connections
|
13×16×7mm³
|
12×15×7mm³
|
29×18×11mm³
|
Features
|
Analogue sensor
with nearly unlimited resolution
|
Analogue sensor
with
nearly unlimited resolution
|
Analogue sensor
with
nearly unlimited resolution
|
For very low
pressures
|
Different accuracy
classes available
|
Different accuracy
classes available
|
Excellent offset
stability
|
Virtually no
position sensitivity
|
Model
|
HCLA
|
HCE
|
HDI
|
Pressure ranges
|
2.5 to 75 mbar
|
10 mbar to 5 bar
|
10 mbar to 5 bar
|
1 to 30 inH2O
|
4 inH2O to 70 psi
|
4 inH2O to 70 psi
|
Pressure type
|
Gage, Differential
|
Absolute, Gage,
Differential
|
Absolute, Gage,
Differential
|
Output signal
|
0.25-4.25 V, I²C
bus
|
0.25-4.25 V, SPI
bus
|
0.5-4.5 V, I²C bus
|
Accuracy,
non-linearity
|
±0.05 %FSS
|
±0.1 %FSS
|
±0.1 %FSS
|
Accuracy, total
accuracy
|
N.A.
|
±0.5 %FSS
|
±0.5 %FSS (P-grade)
|
±1.5 %FSS (H-grade)
|
Temp. range
operating
|
-25-85°C
|
-25-85°C
|
-20-85 °C
|
Dimensions without
connections
|
13×16×7mm³
|
13×16×7mm³
|
12×15×7mm³
|
Features
|
Digital signal
conditioning
|
Digital signal
conditioning
|
Digital signal
conditioning
|
For very low
pressures
|
Very high total
accuracy
|
Very high total
accuracy
|
Excellent offset
stability and virtually no position sensitivity
|
SPI bus interface
and analogue output \at the same time
|
I²C bus interface
and analogue output
at the same time
|
I²C bus interface
and analogue output
at the same time
|
Different accuracy
classes available
|
Model
|
LBA
|
LDE
|
Pressure ranges
|
25 to 500 Pa
|
25 to 500 Pa
|
0.1 to 2 inH2O
|
0.1 to 2 inH2O
|
Pressure type
|
Gage, Differential
|
Gage, Differential
|
Output signal
|
0.5-4.5 V
|
0.5-4.5 V, SPI bus
|
Offset stability
|
0.3 % p.a.
|
0.1 % p.a.
|
Accuracy, total
accuracy
|
±1.5 %FSS
|
±1.5 %FSS
|
Dimensions without
connections
|
13×18×8mm³
|
13×18×8mm³
|
Features
|
Unmatched
sensitivity and resolution
|
Unmatched offset
stability, linearity, sensitivity and resolution
|
Analogue signal
conditioning
|
Digital signal
conditioning with SPI bus interface and analogue
output at the same time
|
Micro-flow channel
integrated
within sensor chip
|
Micro-flow channel
integrated
within sensor chip
|
High immunity to
dust, humidity and long tubing
|
High immunity to
dust, humidity and long tubing
|
Miniature housing
|
Miniature housing
|
Model
|
HMA
|
HMI
|
HME
|
Pressure ranges
|
100 mbar to 10 bar
|
100 mbar to 10 bar
|
101 mbar to 10 bar
|
1 to 150 psi
|
1 to 150 psi
|
1 to 150 psi
|
Pressure type
|
Gage, Differential
|
Gage, Differential
|
Gage, Differential
|
Output signal
|
0.5-4.5 V
|
I²C bus
|
SPI bus
|
Accuracy,
non-linearity
|
±0.25 %FSS
|
±0.25 %FSS
|
±0.25 %FSS
|
Accuracy, total
accuracy
|
±1.5 %FSS
|
±1.5 %FSS
|
±1.5 %FSS
|
Temp. range
compensated
|
-20-85°C
|
-20-85°C
|
-20-85°C
|
Dimensions without
connections
|
10×13×6mm³
|
10×13×6mm³
|
10×13×6mm³
|
Features
|
Increased media
compatibility for gases and liquids
|
Increased media
compatibility for gases and liquids
|
Increased media
compatibility for gases and liquids
|
Digital signal
conditioning
|
Digital signal
conditioning
|
Digital signal
conditioning
|
Analogue output
signal
|
I²C bus interface
|
SPI bus interface
|
Very small housings
|
Very small housings
|
Very small housings
|
Model
|
SSO
|
SSI
|
KMA
|
Pressure ranges
|
200 mbar to 35 bar
|
200 mbar to 35 bar
|
500 mbar to 100 bar
|
3 to 500 ps
|
3 to 500 psi
|
7 to 1500 psi
|
Pressure type
|
Absolute, Gage
|
Absolute, Gage
|
Gage
|
Output signal
|
100mV (FSO)
|
0.5-4.5V, I²C bus
|
0.5-4.5V
|
Accuracy,
non-linearity
|
±0.1 %FSS
|
±0.1 %FSS
|
±0.4 %FSO
|
Accuracy, total
accuracy
|
±1.5 %FSS
|
±1.5 %FSS
|
±1.5 %FSS
|
Temp. range
compensated
|
0-50°C
|
-20-85°C
|
0-85°C
|
Temp. range
operating
|
-40-125°C
|
-40-120°C
|
-20-85°C
|
Dimensions without
connections
|
Φ19mm
|
Φ19mm
|
Φ22×27mm
|
Features
|
High media
compatibility
|
High media
compatibility
|
High media
compatibility
|
Fully welded
stainless steel
construction
|
Fully welded
stainless steel construction
|
Ceramic pressure
sensor element in stainless steel housing
|
Very high total
accuracy
|
I²C bus interface
and analogue
|
output at the same
time
|
Digital signal
conditioning
|
|