| 首页 | 公司简介 | 产品展台 | 开发生产 | 资料下载 | 技术支持 | 解决方案 | 展会消息 |
| 代理经销 | 集成电路 | 高频微波 | 消费电子 | 工控网络 | 安防报警 | 光纤光电 | 汽车电子 |
| 合作交流 | 留言本 | 友情连接 | 热卖产品 | 销售网络 | 招聘加盟 | 新品介绍 | 联系我们 |
|
LDC Captive Guided DC LVDT Displacement Transducer |
![]() |
|
| Rear Mount | Front Mount |
| M5 x 0.8 female, 11mm deep | M5 x 0.8, 15mm long |
| Unit Type | Stroke | Dim. L | Dim. X | Dim. D1 | Dim. A | Weight | Over Travel | |
|---|---|---|---|---|---|---|---|---|
| Inward | Outward | |||||||
| LDC500C | ±12.5mm | 191mm | 38mm | 20.6mm | 23mm | 384gms | 13mm | 10.6mm |
| LDC1000C | ±25mm | 216mm | 63mm | 390gms | 13mm | 10mm | ||
| LDC2000C | ±50mm | 333mm | 76mm | 511gms | 10mm | 14mm | ||
| LDC3000C | ±75mm | 445mm | 114mm | 625gms | 24mm | 15mm | ||
| LDC4000C | ±100mm | 490mm | 127mm | 767gms | 8mm | 14mm | ||
| LDC6000C | ±150mm | 681mm | 178mm | 1022gms | 12.3mm | 17.2mm | ||
| LDC8000C | ±200mm | 871mm | 254mm | 1448gms | 22mm | 25mm | ||
| LDC10000C | ±250mm | 1067mm | 305mm | 1676gms | 34mm | 35mm | ||
| LDC15000C | ±375mm | 1473mm | 406mm | 2215gms | 12.5mm | 12.5mm | ||
| LDC18500C | ±470mm | 1740mm | 508mm | 2613gms | 5mm | 33mm | ||
The RDP Electronics LDC series are a dc LVDT transducer which makes them probably the most robust position sensor available. The term dc LVDT refers to a position sensor that has all the benefits of the LVDT measurement principle but has built-in dc to dc signal conditioning. Our dc LVDT displacement transducer units have no contact across the position sensor element ensuring very long life. The captive guided dc LVDT displacement transducer units have an internal bearing that guides the armature (the moving part of the measurement sensor). The armature of the dc displacement transducer is fitted with a male thread and the body a female thread in order to ease mounting. This type of dc LVDT transducer is appropriate for applications where the part being measured may move well out of the range of the measurement sensor.
RDP Electronics also manufacture ac LVDT sensors for use where the temperature or other environmental factors preclude the use of dc lvdt transducer units.
A mounting block is available for all 20.6mm diameter dc displacement transducers, and Spherical End Bearings for captive type transducers.
| Electrical Specification | |
| Supply | 5V regulated or 6 to 18V unregulated at 100mA |
| Output | ±2.2V nominal, isolated from supply. |
| Linearity (% error of full scale) | ±0.5% standard. 0.25% and 0.1% optional on some models. |
| Output load (min) (Ohms) | 2k |
| Output ripple | 30mV peak to peak |
| Output bandwidth (Electrical) | 200Hz |
| Output Impedance | 2 Ohms |
| Zero Temperature Coefficient | ±0.01% F.S./°C |
| Span Temperature Coefficient | ±0.03% F.S./°C |
| Operating Temperature Range | -50°C to +70°C |
| Electrical Termination | 2m screened cable (Longer available to order) |
Due to the RDP Electronics policy of on-going development, specifications may change without notice.
Any modification may affect the specification of our equipment.