Model 3000RS
Portable Trace H2S
Analyzer with
Complete Sample
System |
|
• |
High-resolution
3 ½ digit single
range LCD |
|
• |
3 Standard
analog output
ranges: 0-10ppm,
0-50ppm,
0-100ppm,
optional ranges
available. |
|
• |
0-1VDC analog
output |
|
• |
Data logger.
Logs data for 15
days @ 1min
intervals, 30
days @ 2min
intervals, etc |
|
• |
Patented pending
cellblock
technology
includes a flow
control valve,
flow meter and
gas connections
all integral to
the compact cell
block.
|
|
• |
3 year life
expectancy
high-performance
electrochemical
sensor. Quick
and simple to
replace when
necessary |
|
• |
Rechargeable
NiCad batteries |
|
• |
Very compact and
rugged |
|
• |
Designed to meet
intrinsic safety
requirements |
|
|
|
|
|
|
|
|
|
Permanent Mounted Sample Pump |
|
• |
Handles wide pressure ranges from 14"Hg. to 10psig. |
|
• |
Designed for Class 1, Div. 2, Group C,D Area Classifications |
|
• |
Long life pump and motor, 20,000 + hrs. continuous |
|
• |
Unique pump diaphragm that is virtually non diffusive for low level trace applications |
|
• |
Power requirements: 12VDC @ 700mA |
|
|
|
|
|
|
|
|
Portable Sample Pump |
|
• |
Handles wide pressure ranges from 14"Hg. to 10psig. |
|
• |
Designed for Class 1, Div. 2, Group C,D Area Classifications |
|
• |
Long life pump and motor, 20,000 + hrs. continuous |
|
• |
Unique pump diaphragm that is virtually non diffusive for low level trace applications |
|
• |
Rechargeable NiCad batteries operates for 4 hours continuously on a full charge |
|
|
|
|
|
"Guardian" Liquid Rejection Membrane
|
|
|
|
|
"Guardian" Liquid Rejection Membrane |
|
• |
Unique membrane and diaphragm design prevent the occasional slugs of liquid gunk traveling down the gas pipeline from flooding out expensive analytical equipment. Prevents costly repair and down time. |
|
• |
Break through check valve allows gas to flow in one direction only. This prevents "Air" from being drawn into a flammable gas pipeline via the exhaust port in the event the gas field suddenly experiences a vacuum condition. |
|
• |
Available with or without pressure reducing regulator |
|
• |
The Guardian automatically drains liquids back into the pipeline without the need for a bypass gas port, which wastes considerable amounts of flammable gas. |
|
|
|
|
|
|
|
|
|
|
Demister |
|
• |
Very efficiently cools hot saturated sample gas to ambient temperature, causing liquids to coalesce into droplets and return via gravity back to the gas pipeline. The Demister prevents liquids from accumulating down stream in expensive analytical instruments causing costly repairs and down time. |
|
|
|
|
|
|
|
|
Extreme weather Enclosure
|
|
|
|
|
Extreme Weather Enclosure |
|
• |
NEMA 4X Enclosure allows for our heated Model 210BR, 2010BR and 3010BR to be quickly and easily mounted in place for use in extreme cold, wet and windy weather conditions down to -40° F. |
|
• |
Enclosure is predrilled, insulated, powder coat painted and supplied with all hardware for quick and simple installation. |
|
• |
Hardware includes: Explosion proof couplings, explosion proof seal-offs, 316S.S. tubing and gas fittings. |
|
• |
Dimensions: 21.5"W x 16.5"H x 6.5"D |
|
|
|
|
|
Flexible, High Pressure, Non-diffusive
Sample/Calibration Tubing
|
|
|
|
|
Flexible, High Pressure, Non-diffusive Sample/Calibration Tubing |
|
• |
This unique high pressure, non-diffusive sample gas tubing is outfitted with special connection fittings. Designed with an o-ring/swage seal and requiring only finger tightening, the tubing and fittings are rated up to 6,500psig. It continues to provide a leak tight seal even after thousands of connections without causing damage to the female portion of the compression fittings, generally attached to the expensive gas analyzers. |
|
• |
With conventional fittings, damage often occurs after just one reconnection simply due to the metal-to-metal swaging design, resulting in gas leaks. Even very minute leaks can wreak havoc with low level ppm oxygen measurements. |
|
• |
In addition, the plastic tubing is filled with a Kevlar fiber making it virtually non-diffusive and well suited for high pressure applications. This makes for a perfect choice when performing routine calibrations for most gas analyzers, especially trace oxygen. |
|
• |
Other plastic tubing such as: Teflon, Tygon, Nylon or Polyethylene diffuse oxygen generally in the range of 2ppm to 100ppm of oxygen per 15' lengths. The amount of diffusion depends on temperature, flow and pressure. Previously, low level trace oxygen measurement required stainless steel or other metallic tubing which is much too cumbersome and prone to failure for routine calibrations. |
|
• |
Available for all 1/4" swage type compression fittings.
|
|
• |
6,500psig. rating |
|
|
|
|
|
|
|
|
|
|
Auxiliary Power Adapter |
|
• |
Our auxiliary power adapter allows you to recharge the batteries on all AMI portable gas analyzers using the cigarette/auxiliary power adapter in your vehicle. |
|
• |
This handy accessory allows you to keep working in the field without down time in the event you forget to adequately charge your batteries the night before and find yourself miles away from AC power. |
|
|
|
|
|
|
|
Protective Carrying Case |
|
• |
This rugged protective carrying case extends the life of our portable gas analyzers in the most demanding and hazardous environments. |
|
• |
It is lined with a thick die cut foam providing complete protection to your portable analyzer during travel and storage periods. The die cut foam also has built in compartments for the battery charger and quick disconnect fitting, as well as the flexible tubing and Liquid Rejection Probe accessories. |
|
• |
These compartments not only protect them, they keep all the necessary components together and organized. |
|
|
|
|
|
Calibration Gas Nipple with O-ring
|
|
|
|
|
Calibration Gas Nipple with O-ring |
|
• |
This gas nipple with o-ring seal eliminates common leaks associated with imperfect metal to metal surfaces that are common when mating high pressure gas cylinders to pressure reducing regulators. |
|
• |
Leaks of any type are unacceptable while attempting to calibrate low level trace oxygen analyzers. |
|
• |
This inexpensive brass nipple and o-ring combination provides a simple and reliable solution to the common occurrence of leaks produced by metal to metal connections. |
|
• |
This nipple will fit any pressure reducing regulator inlet with a ¼" NPT inlet port. |
|
|
|
|
|
|
|
|
|
|
|
|
|
Model 3010BR
Wall Mount or
2.0" pipe Mount
Hazardous
Location Trace H2S
Analyzer with
Complete Sample
System |
|
• |
High resolution
3 ½ digit single
range LCD |
|
• |
Comprehensive
state-of-the-art
electronics
platform,
includes: simple
and intuitive
user interface,
2-fully
adjustable alarm
relay contacts,
programmable
alarm
configurations,
alarm bypass
feature,
programmable
alarm delays, on
board data
logger,
3-individual
security
settings,
internal
diagnostics,
remaining sensor
life indication,
etc. |
|
• |
3 Standard
analog output
ranges: 0-10ppm,
0-50ppm,
0-100ppm,
optional ranges
available. |
|
• |
1-5VDC and
4-20mA. analog
outputs |
|
• |
Patented pending
cellblock
technology.
Provides 3-way
selector valve:
Sample/Span/Off,
a flow control
valve and flow
meter all
integral to the
compact cell
block |
|
• |
3 year life
expectancy
high-performance
electrochemical
sensor. Quick
and simple to
replace when
necessary |
|
• |
Designed to meet
CSA
International to
UL and CSA
standards as
meeting
requirements for
Class I, Div. 1,
Groups B,C,D
with flammable
gas sample. |
|
|
|
|
|
|
|
|
|
|
|
美国AMI氧分析仪传感器P-2百分含量 美国AMI氧分析仪传感器P-3百分含量 美国AMI氧分析仪传感器P-4百分含量
美国AMI氧分析仪传感器T-1微量 美国AMI便携式微量氧分析仪 美国AMI便携式百分量氧分析仪 美国AMI微量氧分析仪
美国AMI多通道微量氧分析仪 美国AMI防爆微量氧分析仪 美国AMI百分量氧变送器 美国AMI百分量氧分析仪
美国AMI多通道百分量氧分析仪 美国AMI防爆百分量氧分析仪 美国AMI氧气损耗监测器
产品图片 |
产品名称/型号 |
产品简单介绍 |
|
美国AMI氧分析仪传感器P-2百分含量
AMI P-2
|
|
|
美国AMI氧分析仪传感器P-3百分含量
AMI P-3
|
|
|
美国AMI氧分析仪传感器P-4百分含量
AMI P-4
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
日本Figaro气体传感器选型
日本NEMOTO气体传感器
日本FIS气体传感器
英国CITY城市气体 CITY公司/IT公司/SENSORIC公司气体传感器选购指南
英国Alphasense气体传感器选型
瑞士Membrapor气体传感器选型
德国IT公司气体传感器选购资料 德国SENSORIC公司气体传感器 RAE气体传感器气体检测仪 意大利森斯特传感器
Dittrich气体产品
国产气体传感器选型
DCS公司红外产品
VTI公司红外产品
SENSORS公司红外热导产品
爱丁堡公司红外产品Honeywell传感器
SHINYEI传感器
E2V传感器
GE传感器SMARTGAS传感器MSI传感器MEAS传感器
英国SSC气体检测 宝亚呼吸防护设备 Dynament气体传感器德国Schutz
NDIR 红外气体传感器美国MAXTEC产品 美国Teledyne气体分析仪及氧传感器
美国AMI氧分析仪及传感器 美国AII氧分析仪传感器
电化学气体传感器
半导体气体传感器
催化燃烧式气体传感器
固体电解质气体传感器
热传导式气体传感器
红外气体传感器
离子烟雾传感器
机动车用气体传感器
气体变送器/检测仪
O2氧气传感器专场
CO2二氧化碳传感器专场
CH4甲烷传感器专场
室内空气质量监测控制
温湿度监测控制
医疗设备用传感器
红外气体分析元件1
红外气体分析元件2
红外气体分析元件3
激光红外气体分析元件1
激光红外气体分析元件2
激光红外气体分析元件3
气体变送器模块
BW便携式气体检测仪
BW固定式气体检测仪CO传感器
S02传感器H2S传感器
NH3传感器
NO传感器
NO2传感器
CH2O传感器
CL2传感器
HCL传感器
H2传感器O3传感器C2CL4传感器C2H4传感器
HF传感器
HBR传感器
COCL2传感器
HCN传感器
ASCL3传感器
ASF3传感器C4H6传感器
CLO2传感器
SIH2CL2传感器
(CH3传感器NH传感器
GeCL4传感器
I2传感器
PCL3传感器
SICL4传感器
SO2F2传感器
酒精传感器其它 |