Temperature Humidity Pressure Flow Air Quality (VOC) Carbon Dioxide (CO2) Carbon Monoxide (CO) Nitrogen Dioxide (NO2) Toxic Gases Light Level Liquids Warning Smoke Detection Thermostats Valves and Actuators Damper Actuators Weather It support
Nitrogen Dioxide (NO2) Detector
Nitrogen Dioxide (NO2) Detectors are used in applications such as bus- and truck garages, underground garages, road tunnels, engine repair shops, tunnels, engine test benches, shelters, mountain cavities, loading bays with diesel-engined vehicles.
Nitrogen Dioxide (NO2) Detectors are used to warn when the quantity of harmful gases reaches an unhealthy level.
Nitrogen Dioxide (NO2) Detectors are used to ensure that the management of ventilation is done the best and most profitable way, ie. according to fresh air requirements.
When the concentration of Nitrogen Dioxide (NO2) becomes too high, the fans starts automatically and stops again when the Nitrogen Dioxide (NO2) concentration has down to the predetermined level.
The Nitrogen Dioxide (NO2) Detectors have a built-in electrochemical Nitrogen Dioxide (NO2) sensor.
Deluxe version
Gas Central with built-in Gas Detector for
Nitrogen Dioxide (NO2), NO2C-series
- Measuring ranges
0-10 ppm, 0-20 ppm or 0-30 ppm - LCD display to show actual in ppm
- Status LED indication
Normal operation - Fault - Alarm 1 - Alarm 2 - Keyboard
4 push-button - menu-driven - Internal buzzer
- (0)2-10 Vdc or (0)4-20 mA output, jumper selectable
- 2 x relay alarm outputs
Alarm relay 1 for NO2 gas alarm level 1
Alarm relay 2 for NO2 gas alarm level 2 - 2 x binary outputs
- 4-20 mA input for external CO or NO2 detector
Options for Deluxe version,
Gas Central with built-in Gas Detector for
Nitrogen Dioxide (NO2), NO2C-series
- LED flashing light
- Warning lights
- Power relays
- Warning horn
- Heating
- Duct mounting set
- Modbus RS-485
Premium version
Nitrogen Dioxide (NO2) Detector
NO2D-series = wall, plastic IP65.
NO2B-series = duct, plastic IP65.
NO2S-series = wall, stainless steel IP55.
- Supply voltage 18-28 Vac/dc
- Outputs (0)2-10 Vdc or (0)4-20 mA (jumper selectable)
- Ranges are 0-10 ppm or 0-20 ppm
Options for Premium version
Nitrogen Dioxide (NO2) Detector
NO2D, NO2B and NO2S-series:
- Relay Pack (2 alarm relays)
- Buzzer/Siren
- LCD display
- LED indicator
- Heating
- Modbus RS-485
Read more about Nitrogen Dioxide (NO2) Detector, Premium version, NO2D, NO2B and NO2S-series
Basic version
Nitrogen Dioxide Detector (NO2)
NO2A 020VC = wall, plastic IP65.
NO2K 020VC = duct, plastic IP65.
NO2R 020VC = wall, stainless steel IP55.
- Supply voltage 18-28 Vdc
- Outputs 4-20 mA or 2-10 Vdc
- Range 0-20 ppm
Facts about Nitrogen Dioxide (NO2) Detectors
Nitrogen Dioxide or NO2 gas is reddish-brown in color with a sharp characteristic and with arctic odor is a protuberant air pollutant.This harmful gas mostly found in industries where diesel is used as fuel. Exposure of this gas have harmful reactions over our body parts like eye, throat etc. More exposure of this gas can be the cause of death. So protection from this gas is very necessary and important. In this regard Nitrogen Dioxide (NO2) Detectors can help to a great extent. You need not to worry about the risk related to this injurious gas.
Nitrogen Dioxide (NO2) Detectors can detect the gas quantity and warn when the amount of harmful gases touches a harmful level. This type of detectors are used in different applications liketruck and bus garages, road tunnels, underground garages, engine repairing shops, engine test benches, tunnels, shelters, loading bays with diesel-engine vehicles, and in other places where fuel is diesel such as any industry. Nitrogen Dioxide is produced when hydrocarbons burn. Arrangement of these detectors is a good investment to avoid health problems and to avoid different expenditures. For example if a bus garage have this detector, then the workers get warning if the harmful gas level increase and can do their job properly.
To make sure that the arrangement of ventilation is properly done Nitrogen oxide (NO2) Detectors are used. Fresh air must be present as per requirement quantity for a healthy environment.When the level of Nitrogen Dioxide (NO2) becomes high, the fan of the detector startsspontaneously and stops again when the level of Nitrogen Dioxide (NO2) has down to the required level. These detectors have a built-in sensor to detect this unhealthy nitrogen dioxide gas.When Nitrogen Dioxide gas level is high, you can also listen a warning horn. This horn indicates that your environment needs fresh air to reduce this unhealthy gas.
There are different types of Nitrogen Dioxide (NO2) Detectors are available in attractive designs. But in all designs some components are same. Almost all design includes flashing light, warning lights, heating and warning horn. You can choose any model as per requirement. These detectors have a unique feature to identify the Nitrogen Dioxide gas level. The fans in this detector works automatically to facilitate the presence of fresh air and to reduce the Nitrogen gas level.According to the version and model of detectors range to detect Nitrogen Gas varies. Some detectors can measure 0-10 ppm, some 0-20 ppm and some can measure 0-30 ppm.These detectors not only try to minimize the harmful gas level but also warn you about the situation. So, you can aware and arrange proper ventilation in your work area.
These detectors will help you to manage and work in a healthy environment. Many diseases spread due to Nitrogen gas. If you are aware about the advantages of Nitrogen Dioxide (NO2), you will escape from mishaps occur due to this harmful gas in air. Industries can use these detectors to provide a healthy environment and can avoid risks that may occur due to Nitrogen Dioxide gas.