CB102
Twisted, shielded pair cable, red Teflon® jacket, .175" OD,
400 F
-
CB103
Polyurethane jacketed cable, black, twisted, shielded pair,
.250" OD, 250 F
-
CB104
Black polyurethane coiled cable, .210 Dia., AWG=22
-
CB104 (006)
Black polyurethane coiled cable, 6 ft
-
CB104 (010)
Black polyurethane coiled cable, 10 ft
-
CB104 (016)
Black polyurethane coiled cable, 16 ft
-
CB105
Polyurethane jacketed cable, 4 conductor, shielded, .250" OD,
250 F
-
CB108
Light weight, black polyurethane coiled cable, .175 OD,
AWG=24,
-
CB108 (004)
Black polyurethane jacketed, coiled cable, 2 ft retracted, 4
ft. extended, .190 OD
-
CB108 (006)
Black polyurethane jacketed, coiled cable, 2 ft retracted, 6
ft. extended, .190 OD
-
CB108 (010)
Black polyurethane coiled cable, 3 ft retracted, 10 ft.
extended, .190 OD
-
CB108 (016)
Black polyurethane jacketed, coiled cable,4.5 ft retracted,
16 ft. extended, .190 OD
-
CB109
Multi conductor cable, 12 pair
-
CB110
Light weight polyurethane jacketed cable, black, twisted,
shielded pair, .175" OD, 250 F
-
CB111
Twisted, shielded pair cable, yellow Teflon® jacket, .190"
OD, 400 F
-
CB112
3 conductor, shielded cable, white Teflon® jacket, .175" OD,
400 F
-
CB114
Multi conductor cable, 16 pair, twisted, shielded, .740"
diameter, 200 F
-
CB115
Multi conductor cable, 8 pair, twisted, shielded, .545"
diameter, 200 F
-
CB117
Black polyurethane jacketed, 4 conductor, coiled cable
-
CB117 (006)
Black polyurethane jacketed, 4 conductor, coiled cable, 6
foot
-
CB117 (010)
Black polyurethane jacketed, 4 conductor, coiled cable, 10
foot
-
CB117 (016)
Black polyurethane jacketed, 4 conductor, coiled cable, 16
foot
-
CB119
4 conductor orange Teflon® jacketed cable
-
CB122
12 pair Multi-conductor black thermoplastic elastomer (TPE)
jacketed cable, 250 F, .64" OD
-
CB123
6 Conductor Gray Polyurethane Jacketed Cable
-
CB124
Low smoke halogen free 2 conductor cable
-
CB190
Class I, Division 2 cable
-
CB193
CB193RAL Blue polyurethane jacketed cable
-
CB200
Armor jacket ONLY, for CB106 style cable
-
CB202
Stainless steel armor, red Teflon® cable, twisted, shielded
pair, .270" OD, 400 F
-
CB206
Stainless steel armor, twisted, shielded pair, red Teflon®
cable .270" OD, 400° F
-
CB212
3 conductor cable, stainless steel armor, white Teflon® .270"
OD, 400°F
-
CB218
Stainless steel armor protected, 4 conductor Teflon® cable,
twisted, shielded pair, .250" OD, 400 F
-
CB502
Hydraulic hose armor protected, red Teflon® cable, twisted,
shielded pair, .500" OD, 212 F
-
CB506
Twisted shielded pair cable with drain wire, CB206 Internal
Wiring (Belden 88761), heavy duty hydraulic hose tubing outer
jacket
-
CB511
Twisted, shielded pair, yellow Teflon® cable, Hydraulic hose
armor protected, .500" OD, 212 F
-
CB512
Hydraulic hose armor, white Teflon® 3 conductor cable,
twisted, shielded pair, .500" OD, 212 F
-
CB518
Four conductor, twisted shielded cable with drain wire, heavy
duty tubing armor outer jacket
-
CB611
Stainless steel armor protected, CB111 yellow Teflon cable,
.190" diam., twisted, shielded pair, .304" OD armor, 400 F
-
CB802
Stainless steel braided sheathing, CB102, red Teflon® cable,
.175" diam., twisted, shielded pair, .
-
CB806
Twisted, shielded pair, red Teflon® cable .118", stainless
steel braided sheathing, .250" OD, 400 F
-
CB810
Twisted, shielded pair, black light weight polyurethane
jacketed cable, .175" , stainless steel braided sheathing, .250"
OD.
-
CB811
Stainless steel braided sheathing, CB111 Twisted, shielded
pair cable, yellow Teflon® jacket, .190" OD
-
CB812
3 conductor twisted, shielded triad, white Teflon® jacket,
Stainless steel braided sheathing, .250" OD.
-
CB818
4 conductor twisted, shielded cable, red Teflon jacket,.154"
, stainless steel braided sheathing, .250" OD.
-
CB819
4 conductor twisted, shielded cable, orange Teflon jacket,
.190" , stainless steel braided sheathing, .250" OD.
|
-
A2A
MIL-Style 2 socket connector, 250 F, molded from
polycarbonate
-
A2E
MIL-Style right angle, 2 socket connector, 250 F
-
A2L
MIL-Style 2 socket hydraulic hose connector, threaded strain
relief backshell, stainless steel barbed fitting, 250 F
-
A2N
MIL-Style 2 socket connector, molded from Nylon, 250 F
-
A2P
2 socket MIL-Style polyurethane connector, 250 F
-
A2R
MIL-Style 2 socket connector, PPS Material, 350F
-
A2S
MIL-Style, 2 socket connector, all components including
locking ring PPS Material, 350F
-
A2U
Right angle polyurethane molded 2 socket MIL connector
-
A2V
MIL-Style 2 socket right angle connector, High Temp, PPS
Material, 350 F
-
A2Y
MIL-Style right angle, 2 socket connector, molded from Nylon,
250 F
-
A3A
MIL-Style 3 socket connector, 250 F
-
A3E
MIL-Style right angle, 3 socket connector, 250 F
-
A3L
3 Socket MIL-Style connector 250°F
-
A3N
MIL-Style 3 socket connector, molded from Nylon, 250 F
-
A3P
3 socket MIL-Style polyurethane connector, 250 F
-
A3R
MIL-Style 3 socket connector, PPS Material
-
A3S
MIL-Style, 3 socket connector, all components including
locking ring PPS Material, 350F
-
A3U
Right angle polyurethane molded three socket connector
-
A3V
MIL-Style 3 socket right angle connector, High Temp, PPS
Material, 350 F
-
A3Y
MIL-Style right angle, 3 socket connector, molded from Nylon,
250 F
-
B2A
Seal tight boot connector, 2 socket, 250 F
-
B2N
Seal tight boot connector, 2 socket, molded from Nylon, 250 F
-
B2R
Seal tight boot connector, 2 socket, PPS Material, 392°F
-
B3A
Seal tight boot connector, 3 socket, 250 F
-
B3N
Seal tight boot connector, 3 socket, molded from Nylon, 250 F
-
B3R
Seal tight boot connector, 3 socket, PPS material, 350 F
-
C1
7 pin Rockwell / Entek dataline® connector, acceleration
input
-
C10
LEMO 5-Pin Right Angle Connectorr, IRD 943 Interface
-
C22
7 pin LEMO® connector for IRD dataPAC® and enpac®,
acceleration input
-
C23
3 socket D3 style connector for Bently 330400 accelerometer
-*use with CB112, or CB105 multi-conductor cable.
-
C3
25 pin D subminiature connector, CSI acceleration input,
2110, 2115, 2120
-
C302
1/8" Mono plug for Monarch strobe adapter,
-
C303
11 pin Fischer® connector with input from IEPE Triaxial
accelerometer w/Z,X,Y format for use with DLI DCX Data Collector
-
C304
4 socket Switchcraft connector for Commtest vb1000 Tach input
-
C307
5 pin Turck (Blue Reverse Keyed) for Voltage input to CSI
2130 Data collector.
-
C308
5 Pin Turck "C76" Connecor wired for peak view with single
cable & channels A & B
-
C314
Special connector Amphenol ECTA for 01dB Data Collector
-
C315
TURCK REVERSE KEYED FOR TACH - WITHOUT POWER.
-
C316
7 pin LEMO connector with single input from Triaxial sensor,
with (Y,X,Z) format, for use with Datapak/Enpac Data Collectors
-
C317
(4) Socket Twistlok connector for CSI A350-1 sensor (CTC G4H)
-
C320
5 pin Turck connector, wired for Triax Connection, for CSI
2130 Wired as: Y, X, Z
-
C325
6 pin Fischer® connector, wired for Triax input to SKF GX/AX
series Microlog and DLI DCA-31 data collector, configuration Y,
X and Z
-
C329
Tyco/Amp "socket" connector for CSI 404 Tach input (Assembly
Operations:2 Fill)
-
C330
4 Pin LEMO for CSI SPEEDVUE
-
C331
db9 pin connector wired for CSI 2120 Speedvue input
-
C333
(4) Socket Jack for Sensodeck Data Collector [Female]
(Amphenol Part #C16-1 T3109) Assembly Operation: 2 fill)
-
C342
(4) Socket Tyco/AMP connector for DLI DCX/DCA adaptor cable
-
C345
11 pin Fischer® connector, single axis acceleration, for use
with DLI Watchman®
-
C350
3 pin DIN connector for SUS in South America
-
C351
7 pin LEMO connector with single input from Triaxial sensor,
with (X,Y,Z) format, for use with Datapak/Enpac Data Collectors
-
C359
DB25 connector with Slide lock, with single input from IEPE
style accelerometer to Microlog Data Collector and additional
3.5 stereo plug for Headphones.
-
C364
7 pin Fischer®, SKF Microlog Tach input for use with BNC
connector
-
C368
7 pin Fischer® for Tach input to Enpac 1200 use with
CB108/CB110 cable ONLY
-
C371
(3) socket, cable connector for "Break-Away" cable
assemblies. Mates with C372. DATA COLLECTOR END
-
C372
3 pin connector BREAK-AWAY for use with sensor side of cable
assemblies.
-
C382
(4) socket Tyco w/Screw Clamp Backshell for DLI triax
-
C391
2 into 1 custom molded cable adapter with 2 BNC jack
connectors with Channel 1 marked with a yellow tag and
acceleration label and Channel 2 marked with a blue tag and
temperature label. MADE FOR MSC/SIGMA
-
C395
Commtest Tach input connector with (4) pin LEMO for VB7 data
collector, This is a (2) wire configuration for TTL Inputs ONLY
**NOTE - FOR USE WITH CB110 CABLE ONLY****
-
C4
25 pin D subminiature connector, SKF acceleration input, CMVA
series
-
C412
(4) Socket Tyco/AMP connector to mate with C411 connector as
CSI 404 Photo Tach extension cable.
-
C416
7 pin LEMO connector for Triaxial style sensors, input to
chan#2, chan#3, chan#4, and X,Y,Z format, only. For use with vb6
and vb8 series Data Collectors
-
C419
Triax Connector (5) Pin Turck, for Use with CSI 2130 Data
Collector, Wired as: X, Y, Z
-
C420
Triax Connector (5) Pin Turck, for Use with CSI 2130 Data
Collector, Wired as: Z, X, Y
-
C429
(5) pin "Turck" connector with right angle backshell for use
with CSI 2130 analyzer - "Acceleration" input- single channel
-
C430
(5) pin right angle M12 (Turck) - REVERSE KEYED for use with
CSI 2130 Tach inputs with power for speed view.
-
C445
25 pin connector wired for CSI 2130 triaxial input in the Y,
X and Z format.
-
C451
C451 connector single channel acceleration input primarily
used for Commtest Models Vb6 and vb8 only
-
C452
Amphenol ECTA connector wired for triax
-
C460
3.5 mm Stereo plug, mates to 16 position connector for Irvin
Pulp Intermec 700 to Raytek Raynger MX Temperature gun.
-
C464
(4) Socket Twistlok connector for Triax sensor (CTC G4H1) in
the X,Y,Z format, For use with vb8 series Data Collectors and
IMI Triax
-
C465
5 pin M12 connector, connects 5 socket M12 Connector,
-
C466
5 Socket M12 connector, connects 5 Pin M12 Connector,
-
C471
(5) socket, cable connector for Triax Sensor "Break-Away"
cable assemblies. THIS IS THE DATA COLLECTOR SIDE OF CABLE
ASSEMBLY. Mates with C472, for (5) pin sensor side of cable
assembly.
-
C475
E3C, Multi-channel BNC connectors, molded cables with 3 BNC
jacks IN and 1 cable out, Labeled for use with Comtest vb8 as
Green Wire "X" Axis Channel 2, Red Wire "Y" Axis Channel 3 and
White wire "Z" Axis Channel 4
-
C476
F3C, Multi-channel BNC connectors, molded cables with 3 BNC
jacks IN and 1 cable out, Labeled for use with Comtest vb8 as
Green Wire "X" Axis Channel 2, Red Wire "Y" Axis Channel 3 and
White wire "Z" Axis Channel 4
-
C477
4 Pin Lemo, for tach input to vb6 thru vb8. Wired for compact
commtest tach.
-
C478
5 Socket M12 connector for use with Commtest compact laser
tach.
-
C484
6 pin Fischer® connector, wired for Triax input to DLI DCA-31
data collector, configuration X, Y and Z
-
C49
25 pin connector, wired for CSI velocity input, pin 22=(+),
pin 23=(-)
-
C490
TNC jack connector
-
C498
4 socket Switchcraft connector for Commtest vb2000 Tach input
with power, mates to C478 for Commtest laser Model mniVLS
-
C50
25 pin connector wired for CSI 2120 triaxial input
-
C509
3 socket MIL connector with custom bending strain relief,
wired for biaxial AC119-1D sensor. 250 F
-
C516
6 socket Fischer® connector, wired to mate with (C66) 6 pin
Fischer®
-
C517
mini-MIL 4 socket connector, wired for shield drain pass
through using three conductor wire.
-
C518
mini-MIL 4 socket connector, wired for shield drain pass
through using two conductor wire.
-
C519
MIL-Style 3 socket connector, wired for interface to biaxial
AC119-1D sensor, molded from polycarbonate for permanent
installations, 250 F
-
C52
8 Pin LEMO FGG.1B with 308 insert
-
C520
(5) pin right angle M12 (Turck) - REVERSE KEYED for use with
CSI 2130 Tach input without power.
-
C521
Multi-channel BNC connectors, molded cables with 4 BNC plugs
IN and 1 cable out for triaxial sensors X, Y, Z, and Shield
-
C522
5 socket M12 connector mates to C76 connector for single
channel acceleration input to CSI 2130
-
C524
25 pin D subminiature connector, CSI acceleration input on
channel one and voltage input on channel two, applicable for
models 2110, 2115, 2120 and 2130. Mates to C391 connector only.
-
C527
Single channel input for VBOX3 analyzer
-
C531
8 pin circular connector for single axis acceleration input
to Leonova Diamond data collector.
-
C533
8 pin circular connector for triaxial acceleration input to
Leonova Diamond data collector.
-
C538
MIL-Style 2 socket connector, 250 F, molded from
polycarbonate, & cable retention ferrule
-
C542
6 pin connector for use with Schenck data collectors.
-
C543
3 socket connector, twist lock, 250 F
-
C544
5 pin straight Turck connector, for Biaxial acceleration
input to CSI 2130
-
C545
5 pin right angle Turck connector, for Biaxial acceleration
input to CSI 2130
-
C546
4 pin M12 connector for use with DLI Trio Data collectors.
-
C547
7 pin circular connector for tach input to SKF Microlog
series data collectors, mates with C478 connector for MiniVLS
type laser tach.
-
C548
3 pin connector for use with Hazardous area rated sensors,
Pin A signal, pin B common and pin C shield/drain pass through.
Mates with C549 connector only. Based on R3C connector.
-
C550
Turck 5 pin connector for channel "D" input to CSI 2140
-
C551
C551 - 3 socket MIL hydraulic hose connector with backshell
cable strain relief and stainless steel barbed fitting, 250 F
for use with CTC biaxial sensors and 4 conductor cable; Green=X
axis, White= Z Axis, Black = Common, Red conductor not used.
-
C555
5 Pin M12 connector, for Channel "A" acceleration input to
CSI 2130 & CSI 2140
-
C57
25 pin CSI connector, wired for 3 pin biaxial accelerometer
-
C58
DB25 pin connector with slide lock with single input to
channel 1-acceleration, channel 2 Peakvue*
-
C66
6 pin Fischer® connector, for SKF CMXA50, Diagnostic
Instruments DI225 and DLI DCA-20
-
C76
5 pin Turck connector, for acceleration input to CSI 2130
-
C79
TNC Plug connector
-
C80
3 socket connector wired for IMI biaxial sensor (formerly "Q"
connector)
-
C84
7 pin connector, acceleration input, for use with Adash A4300
and NRS VA3
-
C88
CSI-25 pin D subminiature connector, **Special** Wired for
multiple inputs into connector, wired single input to channel A
and single input to channel B
-
C91
6 pin connector, acceleration input, for use with Vibrotest
60
-
C96
10 pin circular connector with single input from IEPE style
accelerometer to Snapshot Data Collector
-
C97
5 pin Turck reverse keyed connector wired for SpeedVue input
only on CSI 2130.
-
CF-C3
25 pin connector kit for use with CSI data collectors, for
cable diameter .250"", 250 F;
-
D2C
2 socket MIL connector with custom bending strain relief, 250
F
-
D2CG
2 socket MIL connector with custom bending strain relief
grounded at sensor, 250 F
-
D2CG1
2 socket MIL connector with custom bending strain relief
grounded at sensor, mates to Entek/IRD 7 pin Lemo connector, 250
F
-
D2D
Right angle 2 socket MIL connector with backshell cable
strain relief, 250 F
-
D2DG
Right angle 2 socket MIL connector, grounded backshell, with
backshell cable strain relief, 250 F
-
D2DG1
Right angle 2 socket MIL connector with custom bending strain
relief grounded at sensor, mates to Entek/IRD 7 pin Lemo
connector, 250 F
-
D2H
2 socket MIL connector with backshell cable strain relief,
250 F
-
D2J
2 socket MIL connector with backshell cable strain relief,
350 F
-
D2M
2 socket MIL connector with backshell cable strain relief,
250 F, with SS barbed fitting
-
D2Q
Class I, Division 2, 2 socket MIL connector with backshell
cable strain relief, 250 F
-
D3C
3 socket MIL connector with custom bending strain relief, 250
F
-
D3H
3 socket MIL connector with backshell cable strain relief,
250 F
-
D3M
3 Socket MIL-style for Hydraulic hose armor
-
E
BNC jack connector
-
E2C
Multi-channel BNC connectors, molded cables with 2 BNC jacks
IN and 1 cable out, Channel 1 Red tag and Channel 2 White tag .
-
E3C
Multi-channel BNC connectors, molded cables with 3 BNC jacks
IN and 1 cable out
-
E4C
Multi-channel BNC connectors, molded cables with 4 BNC jacks
IN and 1 cable out
-
EBLK
"E" Connector (BNC Jack) installed on cable with Black
protective boot installed over "E" connector. (assembly
operation: 2fill)
-
EMPP
BNC measurement point with protector.
-
ERED
"E" Connector (BNC Jack) installed on cable with Red
protective boot installed over "E" connector. (assembly
operation: 2fill)
-
EX
BNC jack connector
-
F
BNC Plug Connector
-
F2C
Multi-channel BNC connectors, molded cables with 2 BNC plugs
IN and 1 cable out
-
F3C
Multi-channel BNC connectors, molded cables with 3 BNC plugs
IN and 1 cable out
-
F4C
4 into 1 custom molded cable adapter, with (4) BNC F ( plug )
connectors, Channel 1 Red tag, Channel 2 Green tag, Channel 3
White tag and Channel 4 Blue tag.
-
FRED
"F" Connector (BNC Plug) installed on cable with Red
protective boot installed over "F" connector. (assembly
operation: 1fill)
-
FX
BNC plug (pin) connector epoxy filled.
-
FX90
Right angle BNC plug (pin) connector
-
FX92
Multi-channel Right angle BNC plug (pin) connector molded
cables with 2 BNC plugs IN and 1 cable out
-
FX93
Multi-channel Right angle BNC plug (pin) connector molded
cables with 3 BNC plugs IN and 1 cable out
-
FX94
Multi-channel Right angle BNC plug (pin) connector molded
cables with 4 BNC plugs IN and 1 cable out
-
FXBLK
"F" Connector (BNC Plug) epoxy filled, installed on cable
with Black protective boot installed over "F" connector,
-
G3H
3 socket connector, twist lock, 250 F
-
G4H1
4 socket connector, twist lock, Y, X and Z configuration. 250
F
-
J2A
2 socket mini-MIL connector, permanent mount, 250 F
-
J2C
2 socket mini-MIL connector with polyurethane strain relief,
for use with CTC small sensor line, portable measurements, 250 F
-
J2N
2 socket mini-MIL connector, permanent mount, molded from
Nylon, 250 F
-
J2P
2 socket mini MIL polyurethane connector, 250 F
-
J4A
4 socket connector, permanent mount, 250 F
-
J4C
4 socket connector, portable measurements, 250 F
-
J4N
4 socket mini-MIL connector, permanent mount, molded from
Nylon, 250 F
-
J4P
DO NOT USE, JXP CONNECTORS ARE ONLY TO BE MOLDED ON
NON-TEFLON .175" CABLING.
-
K2C
Medium size 2 socket connector for portable data collectors
-
L
Tinned leads
-
M2A
4 socket M12 molded connector with 2 live sockets, molded
from Polycarbonate, 250 F
-
M2N
4 socket M12 molded connector with 2 live sockets, molded
from Nylon, 250 F
-
M2P
4 socket M12 molded connector with 2 live sockets, molded
from Polyurethane, 250 F
-
M4A
4 socket M12 molded connector, molded from Polycarbonate, 250
F
-
M4N
4 socket M12 molded connector, molded from Nylon, 250 F
-
R2C
2 Pin MIL-style connector
-
R2CG
2 Pin MIL-style connector with grounded backshell.
-
R2H
2 Pin MIL-style connector with backshell cable strain relief,
250 F
-
R2J
2 pin MiniMIL connector, mates with J2 series connectors
-
R3C
3 Pin MIL-style connector
-
R3H
3 Pin MIL-style connector with backshell cable strain relief,
250 F
-
V2N
Seal tight Viton boot with MIL-Style 2 socket connector,
molded from Nylon, 250 F
-
V2R
Seal tight Viton boot with MIL-Style 2 socket connector,
molded from PPS Material, 350 F
-
V3N
Seal tight Viton boot with MIL-Style 3 socket connector,
molded from Nylon, 250 F
-
V3R
Seal tight Viton boot with MIL-Style 3 socket connector,
molded from PPS Material, 350 F
-
Z
Blunt Cut
|