    ATF-26884
    S Parameters at 5 V 30 mA

 

The following file can be copied for use in frequency domain simulators. Highlight the text between the horizontal rules by dragging you mouse over it, then copy to the clipboard (in most browsers, do this using the Edit pull down menu or enter CTRL+C).


   


!ATF-26884
!S-PARAMETERS at Vds=5V  Id=30mA.   LAST UPDATED 07-22-92

# ghz s ma r 50 

2.0	.94	-41	2.88	138	.029	65	.84	-23
3.0	.87	-65	2.97	118	.043	51	.80	-34
4.0	.79	-89	2.93	97	.053	40	.74	-44
5.0	.71	-109	2.73	79	.057	35	.71	-53
6.0	.64	-126	2.54	64	.060	33	.69	-60
7.0	.57	-142	2.38	50	.063	31	.69	-67
8.0	.52	-162	2.30	35	.070	30	.69	-76
9.0	.48	174	2.21	18	.080	28	.67	-87
10.0	.48	149	2.11	1	.095	24	.63	-100
11.0	.48	130	1.97	-14	.104	22	.57	-114
12.0	.49	108	1.91	-25	.125	20	.55	-122
13.0	.53	88	1.82	-39	.155	18	.54	-132
14.0	.57	69	1.71	-55	.173	5	.52	-146
15.0	.62	56	1.60	-75	.182	-1	.52	-165
16.0	.70	44	1.53	-87	.205	-16	.52	165
17.0	.75	33	1.41	-103	.226	-28	.54	135
18.0	.74	24	1.30	-117	.210	-44	.63	114