    HPMX-3002
    S Parameters at 6 V, Vc = 1.6 V

 

The following file can be copied for use in frequency domain simulators. Highlight the text between the horizontal rules by dragging you mouse over it, then copy to the clipboard (in most browsers, do this using the Edit pull down menu or enter CTRL+C).


   


!      HPMX-3002       S PARAMETERS
!      Vcc1=4.5 V, Vcc2=6 V, Vcontrol = 1.6 V
!       LAST UPDATED 01 07 94

# ghz s ma r 50 

0.10	0.26	122	214.70	160	0.001	111	0.58	-30
0.20	0.18	67	154.92	99	0.001	133	0.49	-33
0.30	0.15	30	122.46	65	0.002	139	0.52	-40
0.40	0.12	-1	104.17	38	0.003	149	0.59	-52
0.50	0.08	-30	95.89	6	0.006	148	0.66	-68
0.60	0.02	-112	90.91	-29	0.008	142	0.71	-89
0.70	0.13	92	79.70	-71	0.010	137	0.65	-114
0.80	0.19	51	57.23	-109	0.013	135	0.50	-131
0.90	0.23	34	39.99	-142	0.016	134	0.34	-143
1.00	0.24	11	26.42	-168	0.019	132	0.29	-139
1.10	0.24	4	18.82	166	0.023	129	0.34	-137